Evaluation of the ADVIA Centaur TSH-3 assay.
نویسندگان
چکیده
An analytical evaluation of the thyroid stimulating hormone (TSH-3) assay on the Bayer ADVIA Centaur immunoassay system was performed. General analytical requirements (linearity, resistance to typical interferences, absence of a carry-over effect) were fulfilled and reproducibility was satisfactory. Inter-assay coefficient of variation (CV) of a human serum pool with a concentration of 0.014 mU/l was 22.3%; at concentrations between 0.26 and 83 mU/l CV was below 6%. Method comparison study demonstrated close agreement of TSH results compared to those obtained with the Roche Elecsys 2010 TSH assay (ADVIA Centaur = 1.08 x Elecsys - 0.18 mU/l; r=0.987; n=324). Handling and practicability of the ADVIA Centaur system proved to be convenient with a very high sample throughput. We conclude that the ADVIA Centaur TSH-3 assay meets requirements for clinical use.
منابع مشابه
Should functional sensitivity of a new thyroid stimulating hormone immunoassay be monitored routinely? The ADVIA Centaur TSH3-UL assay experience.
OBJECTIVES We emphasize the importance of routine follow-up of subnormal TSH concentrations with QC materials. DESIGN AND METHODS The functional sensitivity (FS) of the ADVIA Centaur system TSH assay was assessed. We report the values yielded for QC materials in two clinical laboratories. RESULTS The FS was <0.02 mIU/L. The low-TSH QC (a serum pool) showed unacceptable between-lot imprecisi...
متن کاملThyroid-stimulating hormone and free thyroxine on the ADVIA Centaur immunoassay system: a multicenter assessment of analytical performance.
OBJECTIVES We assessed the analytical performance of the TSH and FT4 assays on ADVIA Centaur in a multicenter national evaluation. DESIGN AND METHODS A precision study and a method comparison were performed. Reference values stated by the manufacturer were checked from 379 normal subjects. RESULTS For TSH and FT4, the intra-assay CVs were below 2.3 and 5.2%, respectively, and the inter-assa...
متن کاملThe biological variation of C-reactive protein in polycystic ovarian syndrome.
lated to be the dose in the equation with a total CV of 20%. We found the functional sensitivity, using reagent lots 26 and 29, to be 0.012 mIU/L. This value is considerably lower than that of Rawlins and Roberts (1 ), although the same reagent lots were used. For the two newer in-date lots, functional sensitivity was calculated to be 0.022 mIU/L. Both determinations are consistent with the man...
متن کاملPerformance evaluation of Siemens ADVIA Centaur and Roche MODULAR Analytics E170 Total 25-OH Vitamin D assays.
OBJECTIVES To evaluate the newly developed Roche MODULAR Analytics E170 Total Vitamin D and the Siemens ADVIA Centaur Vitamin D Total assays. MATERIALS AND METHODS Assays were evaluated using the Clinical and Laboratory Standards Institute protocols. Split patient samples were compared with LC-MS/MS and DiaSorin LIAISON assays (n=79 including 15 specimens with detectable endogenous 25-OH vita...
متن کاملPerformance characteristics of six third-generation assays for thyroid-stimulating hormone.
BACKGROUND Thyroid-stimulating hormone (TSH) is used to detect primary hypo- and hyperthyroidism. Current guidelines for TSH assays recommend a functional sensitivity of < or =0.02 mIU/L. The protocol for determining the functional sensitivity of TSH assays specifies analyses of serum samples with two reagent lots over a 6- to 8-week period. METHODS We determined the functional sensitivities ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry and laboratory medicine
دوره 38 4 شماره
صفحات -
تاریخ انتشار 2000