An Experimental Study on Holdup Measurement in Fluidized Bed by Light Transmission
نویسندگان
چکیده
Nowadays, fluidized bed plays an important part in industry. The design of this kind of reactor requires knowing the interfacial area between two phases and this interfacial area leads to calculate the solid holdup in the bed. Consequently achieving interfacial area between gas and solid in the bed experimentally is so significant. On interfacial area measurement in fluidized bed with gas has been worked, but light transmission technique has been used less. Therefore, in the current research the possibility of using of this technique and its accuracy are investigated. Measuring, a fluidized bed was designed and the problems were averted as far as possible. By using fine solid with equal shape and diameter and installing an optical system, the absorption of light during the time of fluidization has been measured. Results indicate that this method that its validity has been proved in the gas-liquid system, by different reasons have less application in gas-solid system. One important reason could be non-uniformity in such systems. Keywords—Fluidization, Holdup, Light Transmission, Twophase system.
منابع مشابه
CFD Modeling of Cold-Flow Fluidized Beds and Validation with X-ray Computed Tomography
The hydrodynamics in a 152 mm ID bubbling fluidized bed filled with 500-600 μm glass beads have been simulated using the computational fluid dynamics (CFD) code Fluent 6.3, and the results are compared to experimental data obtained using pressure measurements and 3D X-ray computed tomography. The grids in a Cartesian coordinate system used in simulations are made by 2D (8×8 mm, 4×4 mm, 2×2 mm, ...
متن کاملCharacterization of the hydrodynamic structure of a 3D acoustic fluidized bed
............................................................................................................................. xi CHAPTER 1: INTRODUCTION ................................................................................................ 1 1.1 Motivation ............................................................................................................................. 1 1....
متن کاملAn Electrical Conductivity Method for Axial Gas and Solid Holdup Determination in Three Phase Fluidized Beds
ISSN 2277 5056 | © 2012 Bonfring Abstract--Fluidization is an operation in which solid particles are kept under suspension supported by the upward flow of liquid/gas phase. In classic fluidization the solids density are higher than the liquid, where as in Inverse fluidization the solids density are lower than that of continuous liquid phase. The phase holdup measurements in three phase classic/...
متن کاملExperimental Study of Coating in a Bottom Sprayed Fluidized Bed
Several investigations have been devoted towards understanding the coating process in fluidized beds. Most of these studies focused on spraying liquid droplets over the bed. However, due to the complexity of these systems, more investigations are still required to quantify the effect of operating conditions on the coating criteria. The present work aims at fundamentally understanding and pr...
متن کاملExperimental Dynamic Evaluation of Three-phase Reactors
The hydrodynamic parameters were determined for two different three-phase systems (fluidized-bed and trickle-bed) through the experimental evaluation of the dynamic residence time distribution in the gas or liquid phase. For different fluid phase flow rates the fluidized-bed system was operated with a tracer in the gas phase and in the trickle-bed with a tracer in the liquid phase. The analysis...