The influence of lightning induced voltage on the distribution power line polymer insulators

نویسندگان

  • Mahdi Izadi
  • Muhammad Syahmi Abd Rahman
  • Mohd Zainal Abidin Ab-Kadir
  • Chandima Gomes
  • Jasronita Jasni
  • Maryam Hajikhani
چکیده

Protection of medium voltage (MV) overhead lines against the indirect effects of lightning is an important issue in Malaysia and other tropical countries. Protection of these lines against the indirect effects of lightning is a major concern and can be improved by several ways. The choice of insulator to be used for instance, between the glass, ceramic or polymer, can help to improve the line performance from the perspective of increasing the breakdown strength. In this paper, the electrical performance of a 10 kV polymer insulator under different conditions for impulse, weather and insulator angle with respect to a cross-arm were studied (both experimental and modelling) and the results were discussed accordingly. Results show that the weather and insulator angle (with respect to the cross-arm) are surprisingly influenced the values of breakdown voltage and leakage current for both negative and positive impulses. Therefore, in order to select a proper protection system for MV lines against lightning induced voltage, consideration of the local information concerning the weather and also the insulator angles with respect to the cross-arm are very useful for line stability and performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation

 Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...

متن کامل

Effects of RTV coating on the electrical performance of polymer insulator under lightning impulse voltage condition

Located near the equator, Malaysia is a country with one of the highest lightning densities in the world. Lightning contributes to 70% of the power outages in Malaysia and affects power equipment, automated network systems, causes data losses and monetary losses in the nation. Therefore, consideration of insulator evaluation under lightning impulses can be crucial to evaluate and attempt to ove...

متن کامل

Designation of an Indicator for flashover prediction of porcelain and glass insulators based on experimental tests.

Flashover of polluted insulators in contaminated areas is one of the most important factors influencing the operation of transmission and distribution lines and finally line outages. Therefore, it is essential to prevent and detect flashover in the insulators. Hence, utilizing the insulator status monitoring systems and predicting their functions have absorbed a lot of attention over the recent...

متن کامل

Lightning Performance of High Voltage Transmission Lines Protected by Surge Arresters: a Simulation for the Hellenic Transmission Network

Lightning strikes to overhead transmission lines are a usual reason for unscheduled supply interruptions in the modern power systems. In an effort to maintain failure rates in a low level, providing high power quality and avoiding damages and disturbances, plenty of lightning performance estimation studies have been conducted and several design methodologies have been proposed. The protection o...

متن کامل

Lightning - Induced Voltages on Overhead Distribution Lines : Theoretical and Experimental Investigation of related Problems and their Impact on Power Quality

Recent power quality studies have been focused on the source-identification of voltage disturbances at distribution network busses. This paper describes a method aimed at correlating indirect-lightning events with power systems relay operations, associated with voltage dips. The proposed method, based on the coordinated use of the Italian lightning location system CESI-SIRF, the Italian monitor...