Discrete automated chemistry system with tableted reagents.
نویسندگان
چکیده
An instrument/reagent system with tableted reagents has been developed for performing ultraviolet/visible photometric assays. Preformed disposable plastic cuvettes pass through a stationary track every 5 s, providing a maximum throughput of 698 tests/h. The photometric system consists of a single light source with a separate set of light guides for each of eight photometer stations; bichromatic readings are possible at any of seven wavelengths between 340 and 630 nm. Tablets for 30 different analytes have been developed, each of which contains all necessary components for a single determination. Tablets are dispensed from disposable dispensers into cuvettes under the direction of the system's microprocessor and are completely dissolved within 45 s by ultrasonic agitation. Sample volumes range from 2 to 20 microL. Test requests are selected on a cathode-ray tube display, and sample-container bar-code labels are automatically printed. Sample entry is totally random. The system is designed to provide reagent quality control and also serum and reagent blank corrections for each test. Examples of equilibrium, zero-order, and first-order kinetic assays are presented.
منابع مشابه
A new and universal free/bound separation technique for the "CENTRIA" automated radioimmunoassay system.
A new separation procedure based on the double-antibody technique has been adapted to the CENTRIA System. This procedure is universally applicable and lends itself to easy adaptation to commercial RIA kits in which liquid reagents are used. This second antibody is covalently linked to agarose (Sepharose) and the lyophilized powder is subsequently tableted for easy use on the instrument. The tec...
متن کاملComparative interference by haemolysis in automated assays for bilirubin at multiple analyte concentrations
The negative interference caused by haemolysis in manual bilirubin assays contrasts with the positive interference reported for some automated methods utilizing the same basic chemistry. A comparison was therefore made of the haemolysis interference associated with several automated bilirubin methodologies: multilayer film (Kodak Ektachem- total bilirubin (TBil), direct bilirubin (DBil), conjug...
متن کاملAutomated measurement of total cholesterol and triglycerides, in "tandem," on the discrete sample analyzer, Gilford System 3500.
We have developed an automated procedure on a discrete sample analyzer, Gilford System 3500, which alternately measures both total serum cholesterol and triglyceride concentrations as a "tandem" procedure. We used Dow Diagnostic's fully enzymatic, colorimetric reagents and aqueous standards to calculate unknowns ratiometrically. Cholesterol and then triglyceride reagent are dispensed into alter...
متن کاملA tableted enzymic reagent for salicylate, for use in a discrete multiwavelength analytical system (Paramax).
A fully enzymic reagent for determination of salicylate in serum has been developed for use in the Paramax analytical system. The assay, run as an equilibrium determination, is based on the reaction of salicylate with NADPH and oxygen in the presence of salicylate hydroxylase (EC 1.14.13.1) to form catechol, NADP+, carbon dioxide, and water. The reaction is complete within 7 min, after which ti...
متن کاملAutomated titrations: the use of automated multiple flow injection analysis for the titration of discrete samples
Introduction In 1974 Fleet and Ho 1] successfully demonstrated an automated continuous flow titration system using a reagent gradient. This system had a throughput of only ten samples per hour, but it was significant since it demonstrated the principles for titration of discrete samples in continuously flowing streams. Nagy et al. [2,3 ]have also demonstrated a similar approach. In 1977, Ruzick...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 29 9 شماره
صفحات -
تاریخ انتشار 1983