Statistically Based, Spatially Adaptive Noise Reduction of Planar Nuclear Studies

نویسندگان

  • A. Hans Vija
  • Timothy R. Gosnell
  • Amos Yahil
  • Eric G. Hawman
  • John C. Engdahl
چکیده

The data-driven Pixon noise-reduction method is applied to nuclear studies. By using the local information content, it preserves all statistically justifiable image features without generating artifacts. Statistical measures provide the user a feedback to judge if the processing parameters are optimal. The present work focuses on planar nuclear images with known Poisson noise characteristics. Its ultimate goals are to: (a) increase sensitivity for detection of lesions of small size and/or of small activity-to-background ratio, (b) reduce data acquisition time, and (c) reduce patient dose. Data are acquired using Data Spectrum’s cylinder phantom in two configurations: (a) with hot and cold rod inserts at varying total counts and (b) with hot sphere inserts at varying activity-to-background ratios. We show that the method adapts automatically to both hot and cold lesions, concentration ratios, and different noise levels and structure dimensions. In clinical applications, slight adjustment of the parameters may be needed to adapt to the specific clinical protocols and physician preference. Visually, the processed images are comparable to raw images with ~16 times as many counts, and quantitatively the reduced noise equals that obtained with ~50 times as many counts. We also show that the Pixon method allows for identification of spheres at low concentration ratios, where raw planar imaging fails and matched filtering underperforms. Conclusion: The Pixon method significantly improves the image quality of data at either reduced count levels, or low target-to-background ratios. An analysis of clinical studies is now warranted to assess the clinical impact of the method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Shearlet-Based Adaptive Noise Reduction in CT Images

The noise in reconstructed slices of X-ray Computed Tomography (CT) is of unknown distribution, non-stationary, oriented and difficult to distinguish from main structural information. This requires the development of special post-processing methods based on the local statistical evaluation of the noise component. This paper presents an adaptive method of reducing noise in CT images employing th...

متن کامل

Self-Adaptive Morphological Filter for Noise Reduction of Partial Discharge Signals

Partial Discharge assessment in the insulation of high voltage equipment is one of the most popular approaches for prevention of the insulation breakdown. In the procedure of thisassessment, noise reduction of partial discharge signals to get the original PD signal for accurate evaluation is inevitable. This denoising process shall be carried out such a way that the main features of the p...

متن کامل

Adaptive Optimum Notch Filter for Periodic Noise Reduction in Digital Images

Periodic noises are unwished and spurious signals that create repetitive pattern on images and decreased the visual quality. Firstly, this paper investigates various methods for reducing the effects of the periodic noise in digital images. Then an adaptive optimum notch filter is proposed. In the proposed method, the regions of noise frequencies are determined by analyzing the spectral of noisy...

متن کامل

Improved lesion detection from spatially adaptive, minimally complex, Pixon reconstruction of planar scintigraphic images.

Pixon noise reduction was applied to 18 planar images, six each from 99mTc-methylene diphosphonate (99mTc-MDP), 67Ga citrate (67Ga), and (123)I-metaiodobenzylguanidine ((123)I-MIBG) studies. Pixon processing increased patient signal-to-noise ratio, 6.8-11.8 fold. Three specialists preferred processed images 44 of 54 times with good agreement (87%). Most (9/10, p<0.02) of the null and negative p...

متن کامل

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005