Surgical removal of guidewire entrapped within stent struts during percutaneous coronary angioplasty.
نویسندگان
چکیده
There has been a growing trend toward percutaneous coronary angioplasty for complex coronary artery lesions. Stent or guidewire break off or trapping within the coronary artery lumen is a rare complication, but it may have fatal consequences. In such cases, the entrapped device may be removed by either percutaneous route or surgical exploration. Here, we report a patient with guidewire entrapment within the struts of the intracoronary stent during primary percutaneous coronary angioplasty, which necessitated surgical removal and subsequent coronary artery bypass grafting (CABG).
منابع مشابه
Surgical removal of entrapped guidewire fragment following direct circumflex artery angioplasty and stenting
We present a case of a 64-year-old man with coronary artery disease, who underwent a percutaneous coronary intervention of the circumflex artery. As the guidewire was being withdrawn from the target vessel, it became entrapped by the structure of the previously implanted stent. Attempts to retrieve the foreign body were unsuccessful. Changes in electrocardiogram were observed during the procedu...
متن کاملSurgical management for retained distal embolic protection device and fractured guidewire after carotid artery stenting
Entrapment and fracture of carotid angioplasty and stenting hardware is a rare complication of percutaneous stenting procedures. We describe a case of a retained distal filter embolic protection device and guidewire in a 57-year-old male in Beijing, China. After unsuccessful attempts at removal via interventional methods, a second stent was deployed to secure the original hardware in situ, and ...
متن کاملSurgical removal of entrapped and broken percutaneous transluminal coronary angioplasty balloon catheter.
OBJECTIVES The percutaneous coronary artery angioplasty is routinely being used worldwide for the management of short and discrete coronary artery stenosis. The purpose of this report is to address the potentially lethal complication among the variety of surgical problems in conjunction with this procedure. The case also illustrates the potential pitfalls in the management of CAD. METHODS A 6...
متن کاملContemporary Reviews in Interventional Cardiology Bioabsorbable Coronary Stents
Percutaneous coronary intervention (PCI) with bioabsorbable stents has created interest because the need for mechanical support for the healing artery is temporary, and beyond the first few months there are potential disadvantages of a permanent metallic prosthesis. Stents improve immediate outcomes, including profoundly reducing acute vessel occlusion after PCI by scaffolding intimal tissue fl...
متن کاملFatal Subacute Stent Thrombosis Induced by Guidewire Fracture with Retained Filaments in the Coronary Artery
During percutaneous coronary intervention, guidewire fractures are very exceptionally encountered in medical practice, but can cause fatal complications such as intracoronary thrombus formation, embolization and perforation. Removal of the remnant segments of guidewire is important for the prognosis. There are several methods being recommended for the treatment of fractured guidewire remnants. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The heart surgery forum
دوره 18 3 شماره
صفحات -
تاریخ انتشار 2015