Impact of three-dimensional transesophageal echocardiography on prosthesis sizing for transcatheter aortic valve implantation.

نویسندگان

  • Oliver Husser
  • Simon Rauch
  • Dierk H Endemann
  • Markus Resch
  • Julio Nunez
  • Vicente Bodi
  • Michael Hilker
  • Christof Schmid
  • Günter A J Riegger
  • Andreas Luchner
  • Christian Hengstenberg
چکیده

OBJECTIVES To compare aortic annulus diameters obtained by 3D transesophageal echocardiography (TEE) with 2D-TEE and the impact on prosthesis size selection in transcatheter aortic valve implantation (TAVI). BACKGROUND In TAVI the aortic annulus diameter determines prosthesis size. The ideal modality for annulus assessment has not been defined yet. METHODS Annulus diameters in 2D-TEE (long-axis view) and in 3D-TEE (long-axis view in multiple-plane-reconstruction) were compared in consecutive patients with aortic stenosis screened for TAVI. Prosthesis size was selected according to industry guidelines, integrating data from 3D-TEE, angiography and computed tomography. The percentage of cases in which 2D-TEE and 3D-TEE correctly predicted final prosthesis size was calculated. RESULTS Forty-nine patients were studied (Age 80 ± 5, 39% male, logistic EuroScore 17 ± 11%). Annulus diameters from 2D- and 3D-TEE correlated (r = 0.808, P < 0.0001). Mean diameters were significantly larger on 3D- vs. 2D-TEE (23.4 ± 2.2 vs. 22.1 ± 2.6 mm, P < 0.001) with a mean difference of 1.2 mm (limits of agreement: -1.8 to 4.3). The interobserver variability of 2D- and 3D-TEE was 3.5 ± 5.6% and 0.9 ± 5.1%, respectively. Thirty-nine patients underwent TAVI (27 CoreValve™, 12 Edwards Sapien™). The procedure was successful in 37 (95%) patients. Postprocedural regurgitation was none or mild in 89% of the cases with no severe insufficiency. Final prosthesis size was correctly predicted by 2D-TEE in 67% while in 80% by 3D-TEE. Overall, 3D-TEE suggested a different prosthesis size in 26% of all cases compared to 2D-TEE. CONCLUSIONS Aortic annulus measurement by 3D-TEE yields significantly larger diameters than 2D-TEE. This impacts prosthesis size selection in a considerable percentage of cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation.

BACKGROUND Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we examined the accuracy of a novel method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus. METHODS We evaluated the theoretical impact of the measurement of the annulus diamete...

متن کامل

Feasibility of a new method using two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation; a case–control study

BACKGROUND Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we validated a new method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus prior to TAVI. METHODS We analysed 124 patients who underwent successful TAVI using a self-expandable p...

متن کامل

Preparatory balloon aortic valvuloplasty during transcatheter aortic valve implantation for improved valve sizing.

OBJECTIVES This study sought to evaluate whether supra-aortic angiography during preparatory balloon aortic valvuloplasty (BAV) improves valve sizing. BACKGROUND Current recommendations for valve size selection are based on annular measurements by transesophageal echocardiography and computed tomography, but paravalvular aortic regurgitation (PAR) is a frequent problem. METHODS Data of 270 ...

متن کامل

Prosthesis sizing for transcatheter aortic valve implantation--comparison of three dimensional transesophageal echocardiography with multislice computed tomography.

BACKGROUND The complex anatomy of the aortic annulus warrants the use of three dimensional (3D) modalities for prosthesis sizing in transcatheter aortic valve implantation (TAVI). Multislice computed tomography (MSCT) has been used for this purpose, but its use may be restricted because of contrast administration. 3D transesophageal echocardiography (3D-TEE) lacks this limitation and data on co...

متن کامل

FDG-PET/CT for driveline infection in a patient with implantable left ventricular assist device.

can Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography. J Am Soc Echocardiogr 1999;12: 884–900. 21. Wong DT, Bertaso AG, Liew GY, Thomson VS, Cunnington MS, Richardson JD et al. Relationship of aortic annular eccentricity and paravalvular regurg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions

دوره 80 6  شماره 

صفحات  -

تاریخ انتشار 2012