Southwick Osteotomy Stabilised with External Fixator

نویسندگان

  • Predrag Grubor
  • Milorad Mitkovic
  • Milan Grubor
چکیده

INTRODUCTION Epiphysiolysis of the femoral head is the most common accident occurring towards the end of pre-puberty and puberty growth. CASE REPORT The author describes the experience in the treatment of chronic epiphysiolysis in two patients treated by Southwick osteotomy. The site is accessed by way of a 15-cm long lateral skin incision and the trochanteric region is reached through the layers. The osteotomy angles prepared beforehand on a thin aluminium model are used to mark the Southwick osteotomy site on the anterior and lateral sides at the level of the lesser trochanter. Before performing the trochanteric osteotomy, two Mitković convergent pins type M20 are applied distally and proximally, above the planned osteotomy site. A tenotomy of the iliopsas muscle is performed, and then the previously marked bone triangle is redissected up to three quarters of the width of the femur. The distal part of the femur is rotated inwards, so that the patella is turned towards the ceiling. The osteotomised fragments of the femur are adapted, repositioned and fixated by installing an external fixator on the previously placed pins. Two more pins are placed, one proximally and one distally, with a view to adequately stabilising the femur. The patient was mobile from day two after the surgery. If, after the surgery, the lead surgeon realises that there is a requirement to make a correction of 5, 10 and 15 degrees of the valgus, varus, anteversion or retroversion deformity, the correction shall be performed without surgically opening the patient, using the fixator pins. CONCLUSION After performing a Southwick osteotomy it is easier to adapt, reposition and fixate the osteotomised fragments of the femur using a fixator type M20. Adequate stability allows regaining mobility quickly, which in turn is the best prevention of chondrolysis of the hip. It is possible to make post-operative valgus, varus, anteversion and retroversion corrections of 5, 10 and 15 degrees without performing a surgery. Once the osteotomy is healed, the fixator type M20 is removed without any additional surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The development of a novel model of direct fracture healing in the rat

OBJECTIVES Small animal models of fracture repair primarily investigate indirect fracture healing via external callus formation. We present the first described rat model of direct fracture healing. METHODS A rat tibial osteotomy was created and fixed with compression plating similar to that used in patients. The procedure was evaluated in 15 cadaver rats and then in vivo in ten Sprague-Dawley...

متن کامل

Corrective supracondylar humeral osteotomies using the small AO external fixator.

Traditional methods of correcting malunited distal humeral fractures in children involve complex wedge osteotomies held with pins or internal fixation devices. These require a large exposure and challenging fixation. We elected to perform simple transverse osteotomies, without wedges, using a lateral incision. These were maintained by the small AO external fixator. Between 1987 and 2004, five c...

متن کامل

Unstable proximal extraarticular tibia fractures: a biomechanical evaluation of four methods of fixation.

OBJECTIVE To compare the biomechanical stability of extraarticular proximal tibia fractures reconstructed using a double-plate construct, locking plate system, hybrid external fixator, and single lateral periarticular plate, all from the same manufacturer. DESIGN Standardized proximal tibial fractures (AO classification 41-A3.2 and A3.3) in synthetic tibiae were stabilized using one of the fo...

متن کامل

Tibial Lengthening Using a Fixator-Assisted Lengthening Plate: A New Technique

BACKGROUND There are many techniques that are used for limb lengthening. Lengthening a limb over a plate is an alternative choice used in children or when using an intramedullary nail is difficult. OBJECTIVES In this study, we presented a new technique for tibial lengthening using a monolateral external fixator over a lengthening plate. MATERIALS AND METHODS For tibial lengthening, a monola...

متن کامل

The role of the small AO external fixator in supracondylar rotational femoral osteotomies.

Torsional problems of the femur have been traditionally treated by a proximal osteotomy with internal fixation. We elected to perform femoral derotational osteotomies distally. Between September 1994 and April 2001, supracondylar osteotomies were performed on 38 femora in 21 children with torsional and angular deformities. The average age was 9 years (range 5-15 years). Twenty-three femora had ...