The Ablation Properties of CO2 Laser Irradiating to Absorption Media: An In Vitro Study

نویسندگان

  • Sajee Sattayut
  • Kittiwut Hortong
  • Chorpaka Kitichaiwan
چکیده

This study aimed to compare histological affected zone of tissue samples irradiated by defocused CO(2) laser at 1, 2, and 3W continuous wave with and without absorption media. The in vitro experiment was conducted in 70 tissue blocks. The samples were randomly allocated into 7 groups: 10 samples each group, namely, the groups irradiated with 1, 2, and 3W, defocused CO(2) laser for 5 seconds, the groups irradiated with 1, 2, and 3W, defocused CO(2) laser to the absorption media, and the media alone group as a control. Then the samples were stained with Masson's trichrome and measured the affected borders under light microscope at 10 × 10 magnification. There was no histological alteration in the groups irradiated with the defocused CO(2) laser to the absorption media while the groups without using the absorption media showed the tissue alteration by photoablation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Crater Width in Nanosecond Laser Ablation of Ti in Liquids and the Effect of Light Absorption by Ablated Nano-Particles

Micro size craters were created by interaction of nanosecond laser beam with titanium target in liquid media. The dimension of crater i.e. depth and width is important in some applications such as micromachining. When the interaction occurs in liquid environment, the ablated materials from the target expand into the liquid. The ablated material can affect the interaction process if the ablated ...

متن کامل

Comparing the Efficacy of Temperature-Controlled Radiofrequency Tonsil Ablation versus CO2-Laser Cryptolysis in the Treatment of Halitosis

Introduction: Halitosis and foreign body sensation are two common and disturbing symptoms of chronic caseous tonsillitis (CCT). The aim of this study was to compare the efficacy and safety of temperature-controlled radiofrequency (TC-RF) tonsil ablation with CO2-laser cryptolysis (CO2-LC) in the treatment of patients with halitosis caused by CCT.   Materials and Methods: Sixty-two patients who ...

متن کامل

بررسی برهمکنش لیزر Er,Cr:YSGG با بافت سخت دندان

Background and Aims: Nowadays lasers are used as alternatives to the tooth preparation because of reducing pain, bloodshed and stress. The aim of this study was to observe the effect of Er,Cr:YSGG laser on the dental hard tissues. Materials and Methods: For this studty, molar teeth with no caries or dental restoration and enamel cracks were used. The laser power were taken from 0.5, 1, 1.5, ...

متن کامل

Study of laser ablation using nano-second laser pulses

 In this paper, the laser ablation process based on the irradiation of nanosecond pulsed lasers on a copper target surface in the presence of Helium gas is studied. The dynamical behaviors of the generated plasma in the helium gas and evaporated copper at the atmospheric pressure are examined using a laser pulse, laser wavelength of and intensity of 7×1010W/cm2. A one-dimensional thermal model ...

متن کامل

A Study on the Laser Tube Bending Process: Effects of the Irradiating Length and the Number of Irradiating Passes

In this paper, the laser bending process of a circular tube made of mild steel has been investigated experimentally. For this purpose, the effects of the irradiating length and the number of irradiating passes on the main bending angle of a laser bent tube are studied. In addition, the main defects of the laser tube bending process such as lateral bending angle, ovality and thickness variation ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012