Effectiveness of computed tomography attenuation values in characterization of pericardial effusion
نویسندگان
چکیده
OBJECTIVE The aim of this study was to evaluate the effectiveness of computed tomography (CT) attenuation values in the characterization of pericardial effusion. METHODS This study consisted of 96 patients with pericardial effusion who underwent pericardiocentesis. For further diagnostic evaluation of pericardial effusion, all the patients were assessed by thorax CT. CT attenuation values were measured from at least 5 different areas of pericardial fluid by specifying the largest region of interest. The average of these measurements was computed and considered as the CT attenuation value of the patient. The patients were classified into two groups: patients with transudative pericardial effusion and those with exudative pericardial effusion. RESULTS CT attenuation values were significantly higher in patients with exudative pericardial effusion than in those with transudative pericardial effusion [14.85±10.7 Hounsfield unit (HU) vs. 1.13±4.3 HU, p<0.001]. CT attenuation values had a close correlation with the pericardial fluid albumin (r=0.829), protein (r=0.752), and LDH (r=0.708) levels; WBC count (r=0.564); protein ratio (r=0.739); and LDH ratio (r=0.689) as well as the albumin gradient (r=-0.725). A cut-off value of 4.7 HU had 80% sensitivity and 87.7% specificity for the identification of exudative pericardial effusion. In addition, a cut-off value of 6.5 HU had 71.4% sensitivity and 72.3% specificity for the prediction of cardiac tamponade. CONCLUSION In patients with pericardial effusion, CT attenuation values seem to be correlated with the characterization parameters of the fluid and may distinguish exudative pericardial effusion from transudative pericardial effusion. This parameter was also found to be a predictor of cardiac tamponade. CT attenuation values can be a useful tool in the clinical evaluation of patients with pericardial effusion.
منابع مشابه
Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners
Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...
متن کاملPericardial effusion in a dog concurrent with carcinoma of unknown primary origin
Background: Pericardial effusion (PE) due to secondary metastasis has rarely been reported in dogs. Case description: This case describes clinical signs and further diagnostics regarding metastatic carcinoma of unknown primary origin (CUP) in refractory PE of a dog. Findings/treatment and outcome: A nine-year-old, castrated mal...
متن کاملAn iterative method to estimate x-ray attenuation coefficients in computed tomography
Introduction: The basis of image formation in Computed Tomography (CT) lies in the x-ray linear attenuation coefficient of the scanned material. Compton scattering and photoelectric effect are the dominant interactions of the x-ray photons with the subject, in the range of diagnostic radiology. These two coefficients are important in tissue characterization by Dual-Energy CT (D...
متن کاملAcute Chest Pain Related to Pericardial Fat Necrosis
An otherwise healthy 56-year-old woman (BMI, 31 kg/m) presented to our emergency department with acute nonradiating left-sided chest pain. She had no associated dyspnea, fever, or other clinical findings. An electrocardiogram and serum troponin level were unremarkable. Nonenhanced computed tomography (CT) of the chest (Figure 1) showed a left anterior low-attenuation (−80HU) pericardial mass wi...
متن کاملHistogram analysis- a useful tool for tissue characterization in brain CT
Introduction: Pixel value in computed tomography (CT) gives the average linear attenuation coefficient of the scanned material in the path of the x-ray beam, being normalized to that of water. It is known that attenuation coefficient or HU value is a function of the chemical characteristic of the material and of the x-ray energy. The CT image shows the HU value by a shade of gr...
متن کامل