Lung function by tidal breathing in awake healthy newborn infants.
نویسندگان
چکیده
The increasing availability of appliances for measuring lung function in infants may allow clinical and epidemiological applications. The aim of the present study was to establish reference values for tidal breathing lung function in awake newborn infants and to investigate potential sources of variability. Tidal flow-volume loops were measured in 803 awake, healthy infants (427 males and 376 females) and passive respiratory mechanics (single-breath occlusion technique) in 664. Mean postnatal age was 2.7 +/- 0.9 (sd) days, gestational age 39.8 +/- 1.4 weeks and birthweight 3.59 +/- 0.49 kg. Tidal expiratory volume (Vt), peak tidal expiratory flow (PEF), and mid-expiratory flow increased significantly with increasing birthweight. Flow ratios: ratio of time to PEF to total expiratory time (Tpef/Te), ratio of volume to PEF to total expiratory volume (Vpef/Ve); and ratio of tidal flow at 25% remaining expiration to PEF (TEF25/PEF), were highest in 1 day old infants (medians 0.39, 0.46 and 0.81 respectively), decreasing to a minimum in 4-5 day old infants, but were not influenced by birthweight. Tidal flows and flow ratios were higher in males versus females, even after weight adjustment. Respiratory rates correlated significantly with tidal flows (r = 0.66), inversely with Vt (r = 0.40), but not with flow ratios. Mean compliance of the respiratory system was 1.18 ml.cmH2O-1.kg birthweight (95% confidence interval (95% CI) 1.15-1.21) and mean resistance 0.051 cmH2O.ml-1.s (95% CI 0.049-0.054). These results demonstrate that lung function in awake healthy infants varies according to weight, gender and postnatal age.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Measuring tidal breathing parameters using a volumetric vest in neonates with and without lung disease.
Lung function measurement is difficult in unsedated infants; tidal breathing parameters are a useful non-invasive surrogate, but even these measurements cause disturbance from applying a facemask. We investigated a novel volumetric vest system (FloRight), which measures volume changes of the respiratory system from changes in the magnetic fields induced by current-carrying coils around the enti...
متن کاملDifferences in tidal breathing between infants with chronic lung diseases and healthy controls
BACKGROUND The diagnostic value of tidal breathing (TB) measurements in infants is controversially discussed. The aim of this study was to investigate to what extent the breathing pattern of sleeping infants with chronic lung diseases (CLD) differ from healthy controls with the same postconceptional age and to assess the predictive value of TB parameters. METHODS In the age of 36-42 postconce...
متن کاملLung function in awake healthy infants: the first five days of life.
Our main aim was to determine an appropriate time for lung function measurements in infants, prior to environmental influences upon their respiratory tract. Tidal flow-volume loops, respiratory system compliance (Crs) and resistance (Rrs) (single breath passive occlusion technique) were measured in 24 healthy, awake awake infants, at one hour and on the following four days of life to investigat...
متن کاملAssessment of tidal breathing parameters in infants with cystic fibrosis.
Simple methods are needed to assess lung function in infants with cystic fibrosis (CF). This study determined the relationship between simple measurements obtained from tidal breathing with those from more complicated forced expiratory manoeuvres. Healthy infants and infants with CF were recruited from two maternity units and five specialist CF hospitals, respectively. Respiratory rate, tidal v...
متن کاملA comparison of respiratory function in Afro-Caribbean and Caucasian infants.
Race is recognized as an important determinant of lung function in children and adults, but limited data exist for infants. Accurate interpretation of lung function tests during the neonatal period may depend on appropriate values for predicting normality. The aim of this study was to compare tidal breathing parameters, Hering-Breuer reflex (HBR) activity, and total respiratory compliance (Crs)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 7 9 شماره
صفحات -
تاریخ انتشار 1994