Introduction: Magnetic resonance angiography of the extremities can help in the diagnosis of conditions such as peripheral arterial disease and peripheral vascular occlusion. In recent work, non-contrast-enhanced high-resolution flow-independent angiograms of the hand have been acquired with SNR-efficient balanced steady-state free precession (SSFP) imaging [1]. The simple and efficient phase-sensitive (PS) SSFP method [2] was used to remove fat; however, the method suffers from partial volume effects. In the case of small vessels in the vicinity of bone marrow and subcutaneous fat tissue, partial volume averaging leads to a loss of blood signal. Instead, alternating repetition time (ATR) SSFP can be used to suppress fat signal [3]. Partial volume effects are significantly reduced, enhancing the visualization of vascular structure. When B0 inhomogeneity or susceptibility variations are significant, fat suppression will be imperfect in certain regions due to the wedge-shaped stop-band of fatsuppressing ATR. Another ATR image with a shift in the echo-time can be used for fatwater separation through post-processing.
منابع مشابه
Non-contrast-enhanced flow-independent peripheral MR angiography with balanced SSFP.
Flow-independent angiography is a non-contrast-enhanced technique that can generate vessel contrast even with reduced blood flow in the lower extremities. A method is presented for producing these angiograms with magnetization-prepared balanced steady-state free precession (bSSFP). Because bSSFP yields bright fat signal, robust fat suppression is essential for detailed depiction of the vasculat...
متن کاملFat Suppression for Non-contrast-enhanced Peripheral Angiography: Phase-sensitive versus IDEAL SSFP
Introduction: MR angiography is a valuable tool in the diagnosis of vascular diseases. Non-contrast-enhanced flow-independent peripheral angiograms can be produced with magnetization-prepared balanced SSFP if the bright fat signal is suppressed [1]. However, poor fat suppression and banding artifacts can be observed with field inhomogeneity (e.g., over large FOVs). In this work, we compare two ...
متن کاملFlow-independent subtractive non-contrast enhanced MRA using flow insensitive and sensitive SSFP-echo
Introduction: Computer tomographic angiography (CTA) is the gold standard for visualizing the arteries in patients with severe peripheral artery disease (PAD) that require revascularization. However, x-ray dye used in CTA should be avoided in patients with kidney diseases or severe diabetes, which is equally the case for gadolinium contrast agents. Further, CTA exposes patients to ionizing radi...
متن کاملFat-suppressed steady-state free precession imaging using phase detection.
Fully refocused steady-state free precession (SSFP) is a rapid, efficient imaging sequence that can provide diagnostically useful image contrast. In SSFP, the signal is refocused midway between excitation pulses, much like in a spin-echo experiment. However, in SSFP, the phase of the refocused spins alternates for each resonant frequency interval equal to the reciprocal of the sequence repetiti...
متن کاملWideband SSFP: alternating repetition time balanced steady state free precession with increased band spacing.
Balanced steady-state free precession (SSFP) imaging is limited by off-resonance banding artifacts, which occur with periodicity 1/TR in the frequency spectrum. A novel balanced SSFP technique for widening the band spacing in the frequency response is described. This method, called wideband SSFP, utilizes two alternating repetition times with alternating RF phase, and maintains high SNR and T(2...
متن کامل