Reported adverse event cases of methemoglobinemia associated with benzocaine products.

نویسندگان

  • Thomas J Moore
  • Christopher S Walsh
  • Michael R Cohen
چکیده

BACKGROUND Methemoglobinemia (MHb) is characterized by abnormal levels of oxidized hemoglobin that cannot bind and transport oxygen. When induced by benzocaine anesthetic spray and other chemicals, it can result in cyanosis and life-threatening complications. METHODS From 818 439 adverse event reports received by the US Food and Drug Administration from November 1997 through March 2002, we extracted every report for use of a benzocaine product. We classified each case by product type (eg, spray, gel, or solution), by whether MHb was involved, and by the dose given. RESULTS Among 198 reported adverse events of all types associated with benzocaine, 132 cases (66.7%) involved definite or probable MHb. The MHb cases included 107 serious adverse events (81.1%) and 2 deaths (1.5%). In 123 cases (93.2%), the product was a spray; in 2 cases (1.5%), a benzocaine-containing lozenge; and 1 case, a gel. In the 69 cases that specified a dose, 37 (53.6%) indicated that a single spray was applied (approximately the recommended amount). CONCLUSIONS Health professionals involved in endoscopy, intubation, bronchoscopy, or similar invasive procedures using benzocaine-containing sprays should know that (1) administration may cause MHb with potentially serious consequences, (2) identifying the reaction to benzocaine usually requires cooximetry (although it can be implied by symptoms), and (3) treatment involves immediate intravenous administration of 1 to 2 mg/kg of methylene blue.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Poison Control Center Management of Benzocaine Exposures

Benzocaine is a topical anesthetic frequently used in healthcare facilities and in over-the-counter medications in concentrations up to 20%. Benzocaine may induce methemoglobinemia, a condition that impairs the blood’s ability to carry oxygen. The optimal management of exposure to benzocaine remains unclear because serious toxicity is uncommon and may not be dose-related. In 2000, it was estima...

متن کامل

Pediatric Exposures to Topical Benzocaine Preparations Reported to a Statewide Poison Control System

INTRODUCTION Topical benzocaine is a local anesthetic commonly used to relieve pain caused by teething, periodontal irritation, burns, wounds, and insect bites. Oral preparations may contain benzocaine concentrations ranging from 7.5% to 20%. Pediatric exposure to such large concentrations may result in methemoglobinemia and secondarily cause anemia, cyanosis, and hypoxia. METHODS This is a r...

متن کامل

Suspected methemoglobinemia following awake intubation: one possible effect of benzocaine topical anesthesia--a case report.

Methemoglobinemia is a potential negative side effect associated with the use of benzocaine for topical anesthesia. A healthy patient admitted for an outpatient orthopedic procedure developed the clinical symptomatology of methemoglobinemia after topicalization of the airway with benzocaine. The patient subsequently responded to appropriate treatment and was fit for discharge the same day. Meth...

متن کامل

Benzocaine-induced methemoglobinemia.

A case is reported in which a patient developed methemoglobinemia-induced cyanosis while under general anesthesia during surgery for multiple fascial space infections. The cause of methemoglobinemia was 20% benzocaine spray used for local anesthesia before intubation. Acutely developing methemoglobinemia is infrequently encountered in clinical practice. When confronted with cyanosis in the abse...

متن کامل

Benzocaine-induced methemoglobinemia based on the Mayo Clinic experience from 28 478 transesophageal echocardiograms: incidence, outcomes, and predisposing factors.

BACKGROUND The potentially life-threatening condition of methemoglobinemia is characterized by cyanosis, low pulse oximetric readings, and normal arterial Po(2) values. Acquired methemoglobinemia has been linked to the use of the topical anesthetic benzocaine in endoscopic procedures, including transesophageal echocardiography (TEE). Yet, the incidence of benzocaine-induced methemoglobinemia wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of internal medicine

دوره 164 11  شماره 

صفحات  -

تاریخ انتشار 2004