The bone conduction implant: Clinical results of the first six patients

نویسندگان

  • Sabine Reinfeldt
  • Bo Håkansson
  • Hamidreza Taghavi
  • Karl-Johan Fredén Jansson
  • Måns Eeg-Olofsson
چکیده

OBJECTIVE To investigate audiological and quality of life outcomes for a new active transcutaneous device, called the bone conduction implant (BCI), where the transducer is implanted under intact skin. DESIGN A clinical study with sound field audiometry and questionnaires at six-month follow-up was conducted with a bone-anchored hearing aid on a softband as reference device. STUDY SAMPLE Six patients (age 18-67 years) with mild-to-moderate conductive or mixed hearing loss. RESULTS The surgical procedure was found uneventful with no adverse events. The first hypothesis that BCI had a statistically significant improvement over the unaided condition was proven by a pure-tone-average improvement of 31.0 dB, a speech recognition threshold improvement in quiet (27.0 dB), and a speech recognition score improvement in noise (51.2 %). At speech levels, the signal-to-noise ratio threshold for BCI was - 5.5 dB. All BCI results were better than, or similar to the reference device results, and the APHAB and GBI questionnaires scores showed statistically significant improvements versus the unaided situation, supporting the second and third hypotheses. CONCLUSIONS The BCI provides significant hearing rehabilitation for patients with mild-to-moderate conductive or mixed hearing impairments, and can be easily and safely implanted under intact skin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical, Histologic and Histomorphometric Evaluation of Bone Strip Allograft with Resorbable Membrane in Horizontal Alveolar Ridge Augmentation: A Preliminary Study

  Objective: Alveolar ridge preservation in patients with inadequate bone volume is one treatment option for successful implant placement and can be done by using bone graft materials. On the other hand, Ceno Bone has been recently produced by Hamanand Saz Baft Kish Co. as a bone bioimplant of allograft origin. This study aimed to assess the clinical, histologic and histomorphometric results of...

متن کامل

Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...

متن کامل

تغییرات هدایت استخوانی پس از بازسازی زنجیره استخوانچه‌ای گوش میانی

    Background & Aim: The most common surgically treatable causes of hearing loss are middle ear diseases among which the greatest effect is related to ossicular chain dysfunction. Successful ossicular chain reconstruction certainly improves air conduction thresholds and closes air-bone gap in audiograms, but the effect of this procedure on bone conduction thresholds has remained to be elucidat...

متن کامل

Breakthroughs in Bone Conduction Hearing Implants HOW INDUSTRY-LEADING INNOVATION HAS TRANSFORMED CLINICAL AND PATIENT EXPERIENCES

The introduction of the CochlearTM Baha® BI300 Implant and DermaLockTM Abutment (BA400) have significantly improved clinical practices and the patient experience with bone conduction hearing implants. First introduced in 2010, the BI300 Implant is now used by over 50,000 patients worldwide. Of these patients, more than 24,000 have also received the DermaLock Abutment since its introduction in 2...

متن کامل

clinical and radiographic methods of marginal bone loss evaluation after immediate implantation in post-extraction sockets.

Introduction: To achieve the best esthetic and functional results of implantation and patient satisfaction, different protocols of implant therapy have been recommended. Immediate implantation can provide the outcome faster than other protocols making it the treatment of choice. The rate of peri-implant bone resorption should be measured clinically and radiographically as bone support is a key ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 54  شماره 

صفحات  -

تاریخ انتشار 2015