IMPORTANCE Approximately 50% of head and neck cancer survivors experience dysphagia and related morbidity. Intensity-modulated radiation therapy (IMRT) is increasingly used to treat oropharyngeal cancers with excellent oncologic outcomes, but few studies have compared it with conventional 3-dimensional conformal radiation therapy (3D-CRT) to determine whether it can decrease treatment-related toxic and adverse effects. OBJECTIVE To determine whether IMRT improves percutaneous endoscopic gastrostomy (PEG) tube and treatment-related toxicity outcomes compared with 3D-CRT in patients with oropharyngeal squamous cell carcinoma. DESIGN, SETTING, AND PARTICIPANTS Retrospective review of 159 patients with oropharyngeal primary tumors with no history of chemotherapy, radiation therapy, or surgery of the head and neck who underwent definitive treatment with radiotherapy for oropharyngeal squamous cell carcinoma at the Hollings Cancer Center outpatient clinic, Medical University of South Carolina, from 2000 to 2009. INTERVENTION Doses of 70 Gy in 35 daily fractions of radiotherapy delivered via IMRT or 3D-CRT. MAIN OUTCOMES AND MEASURES Primary end points included PEG tube dependence 1 year after radiotherapy start, weight loss during treatment, and change in Eastern Cooperative Oncology Group performance status. Secondary end points included overall and disease-free survival, disease recurrence, and toxic effect profiles. RESULTS The IMRT group (n = 103) had a significantly lower rate of PEG tube dependence 1 year after treatment initiation than the 3D-CRT group (n = 56) for all patients (P = .02) and for those with advanced T stage (P = .01) and a shorter time to PEG tube removal (P < .001). Acute grade 3 or greater toxic effects to skin and mucous membranes occurred less frequently in the IMRT group (P = .02 and P < .001, respectively). The 2 groups did not differ significantly in weight loss, treatment failure (hazard ratio, 0.82 [95% CI, 0.47-1.41]), overall survival (P = .45), or disease-free survival (P = .26). CONCLUSIONS AND RELEVANCE The use of IMRT significantly improves PEG tube and toxicity-related outcomes compared with 3D-CRT in the treatment of oropharyngeal primary cancers. Given the association between mucosal toxic effects, PEG tube dependence, and dysphagia, these findings may be an indication of improved swallowing outcomes with IMRT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma

Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...

متن کامل

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

متن کامل

3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk

Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...

متن کامل

Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer

Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...

متن کامل

Respiratory motion effect on tumor and normal tissue doses in patients with lung cancer, treated with Intensity Modulation Radiation Therapy and Three Dimensional Conformal Radiation Therapy.

Introduction:   The aim of this study is to investigate the effect of respiratory motion during radiation therapy in patient with lung cancer and comparison of dosimetric parameters between Intensity modulation radiation therapy and three-dimensional conformal radiotherapy in lung cancer.   Materials and Methods:   Two CT scan was performred for each pati...

متن کامل

Out-of-field photon dosimetry study between 3-D conformal and intensity modulated radiation therapy in the management of prostate cancer

Background: The present work aims to study the out-of-field photon calculation accuracy of a commercial treatment planning system (TPS), Oncentra, for three-dimensional conformal radiotherapy (3D-CRT) and intensity modulated radiation therapy (IMRT) treatment techniques from Elekta Synergy medical linear accelerator. Materials and Methods: Accuracy of individual out-of-field dose components was...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JAMA otolaryngology-- head & neck surgery

دوره 140 4  شماره 

صفحات  -

تاریخ انتشار 2014