Doppler echocardiographic characteristics of normal and dysfunctioning prosthetic valves in the tricuspid and mitral position.

نویسندگان

  • M Pye
  • N Weerasana
  • W H Bain
  • I Hutton
  • S M Cobbe
چکیده

The Doppler echocardiographic characteristics of 70 prosthetic valves in 35 patients are reported. Twenty nine patients had a Björk-Shiley prosthesis in both mitral and tricuspid positions and six had Carpentier-Edwards valves in both sites. Five of the patients had abnormal tricuspid prostheses on the basis of clinical and echocardiographic criteria. Pulsed wave Doppler echocardiography was used in all examinations. The pressure half times for the normal tricuspid prosthetic valves, 105 (40) ms (Björk-Shiley) and 97 (53) ms (Carpentier-Edwards), were significantly longer than those of normal mitral prosthetic valves, 75 (18) ms (Björk-Shiley) and 83 (15) ms (Carpentier-Edwards). The range of pressure half times for the abnormal tricuspid valves (237-530 ms) was distinct from that of the apparently normal tricuspid prosthetic valves (38-197 ms). There was an increase in the peak velocity of the obstructed tricuspid prosthetic valves (1.69 (0.12) m/s) in comparison with normal prostheses (1.06 (0.26) m/s). The normal range of pressure half times for the Björk-Shiley and Carpentier-Edwards valves in the mitral position is not applicable to the same valves in the tricuspid position. The valve appears to function well with very long pressure half times but a pressure half time of greater than 200 ms coupled with a peak velocity of greater than 1.60 ms without significant valve regurgitation indicates tricuspid obstruction of the tricuspid prosthetic valve.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping.

We studied the value of two-dimensional Doppler echocardiographic color flow mapping for identifying normal transvalve flow profiles and valve malfunction in 20 patients with Björk-Shiley prosthetic valves. Seven patients had Björk-Shiley prosthetic valves in the aortic position alone, seven in the mitral position, and six had prosthetic valves in both the aortic and mitral positions. In 10 pat...

متن کامل

Normal pulsed wave Doppler echocardiographic parameters of Turkmen horses of Iran

Turkmen horse is one of the oldest and purest breeds in the world, but there is no information on Doppler echocardiographic parameters in this horse. In the present study, pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. No cardiac disease was detected with two-dimensional (2-D) real-time, M-mode, and colour flow mapping. D...

متن کامل

Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...

متن کامل

Continuous Wave Doppler Echocardiographic Measurement of Prosthetic Valve Gradients

Studies correlating prosthetic valve gradients determined by continuous wave Doppler echocardiography with gradients obtained by cardiac catheterization have, to date, been limited to patients with mitral and tricuspid prostheses or have compared nonsimultaneous measurements. Simultaneous Doppler and catheter pressure gradients in 36 patients (mean age, 63+13 years) with 42 prosthetic valves (2...

متن کامل

Continuous wave Doppler echocardiographic measurement of prosthetic valve gradients. A simultaneous Doppler-catheter correlative study.

Studies correlating prosthetic valve gradients determined by continuous wave Doppler echocardiography with gradients obtained by cardiac catheterization have, to date, been limited to patients with mitral and tricuspid prostheses or have compared nonsimultaneous measurements. Simultaneous Doppler and catheter pressure gradients in 36 patients (mean age, 63 +/- 13 years) with 42 prosthetic valve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 63 1  شماره 

صفحات  -

تاریخ انتشار 1990