Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis.
نویسندگان
چکیده
OBJECTIVES This study was undertaken to compare the hemodynamic performance of a percutaneous bioprosthesis to that of surgically implanted (stented and stentless) bioprostheses for the treatment of severe aortic stenosis. METHODS Fifty patients who underwent percutaneous aortic valve implantation (PAVI) with the Cribier-Edwards or Edwards SAPIEN bioprosthetic valve (Edwards Lifesciences, Inc., Irvine, California) were matched 1:1 for sex, aortic annulus diameter, left ventricular ejection fraction, body surface area, and body mass index, with 2 groups of 50 patients who underwent surgical aortic valve replacement (SAVR) with a stented valve (Edwards Perimount Magna [SAVR-ST group]), or a stentless valve (Medtronic Freestyle, Medtronic, Minneapolis, Minnesota [SAVR-SL group]). Doppler echocardiographic data were prospectively obtained before the intervention, at discharge, and at 6- to 12-month follow-up. RESULTS Mean transprosthetic gradient at discharge was lower (p < 0.001) in the PAVI group (10 +/- 4 mm Hg) compared with the SAVR-ST (13 +/- 5 mm Hg) and SAVR-SL (14 +/- 6 mm Hg) groups. Aortic regurgitation (AR) occurred more frequently in the PAVI group (mild: 42%, moderate: 8%) compared with the SAVR-ST (mild: 10%, moderate: 0%) and SAVR-SL (mild: 12%, moderate: 0%) groups (p < 0.0001). At follow-up, the mean gradient in the PAVI group remained lower (p < 0.001) than that of the SAVR-ST group, but was similar to that of the SAVR-SL group. The incidence of severe prosthesis-patient mismatch was significantly lower (p = 0.007) in the PAVI group (6%) compared with the SAVR-ST (28%) and SAVR-SL (20%) groups. However, the incidence of AR remained higher (p < 0.0001) in the PAVI group compared with the 2 other groups. CONCLUSIONS PAVI provided superior hemodynamic performance compared with the surgical bioprostheses in terms of transprosthetic gradient and prevention of severe prosthesis-patient mismatch, but was associated with a higher incidence of AR.
منابع مشابه
مقایسه نتایج درمانی بالون والوپلاستی و والوتومی جراحی در بیماران مبتلا به تنگی مادرزادی دریچه آئورت در پیگیری 6 ساله در بخش کودکان بیمارستان قلب شهید رجایی تهران
Background: Balloon valvuloplasty is a relatively new technique for relief of obstruction of aortic valve. The primary results of this procedure are similar to surgical valvotomy with fewer complications and mortality. Materials and methods: One hundred fifty-five patients with congenital aortic stenosis were enrolled in this study over a period of 6 years (1991-1997). Participants were all un...
متن کاملSHORT TERM CLINICAL OUTCOME OF PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY VERSUS SURGICAL CLOSED MITRAL COMMISSUROTOMY
BaIlon mitral valvuloplasty and closed mitral valve conunissurotomy were performed in 450 and 127 patients, respectively. Also, 254 patients with severe mitral stenosis were enrolled in a prospective randomized trial comparing the two procedures. Immediately after balloon mitral valvuloplasty, mean left atrial pressure was 11.38±3.54 mmHg, transmitral valve gradient was 1.8±2 mmHg, and mit...
متن کاملAcquired Infrarenal Abdominal Aortic Coarctation: Treatment with Percutaneous Self Expandable Stent
Abdominal aortic coarctation is an extremely rare vascular pathology. Its etiology can be congenital or acquired. Here we present a case of acquired infrarenal abdominal coarctation in a 66-year-old woman who complained of low back and legs pain. She had no signs of resting lower limb ischemia, with diminished distal pulses and normal blood pressure in upper and lower extremities. Magnetic reso...
متن کاملTranscatheter Aortic Valve Replacement: A Review Article
Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...
متن کاملComparison of hemodynamic and clinical outcomes of transcatheter and sutureless aortic bioprostheses: how to make the right choice in intermediate risk patients.
Current surgical treatment options for aortic valve stenosis (AS), as alternatives to that of conventional operation with a midline sternotomy, include sutureless valve replacement (SUAVR) and transcatheter valve implantation (TAVI). Patients with high surgical risk, or those who are judged to be inoperable, are typically good candidates for the TAVI procedure. The best treatment option in pati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 53 20 شماره
صفحات -
تاریخ انتشار 2009