Comparison between a newly developed PC-based Doppler umbilical artery waveform analyser and a commercial unit.
نویسندگان
چکیده
OBJECTIVES To determine the accuracy of the resistance index (RI) of flow velocity waveforms of the umbilical artery measured using a newly developed PC-based continuous wave Doppler device (Umbiflow) with regard to systematic and random variations when compared with a commercial standard (Vasoflow). DESIGN A cohort study. SETTING The fetal evaluation clinic (FEC) at Tygerberg Hospital. SUBJECTS Patients referred to the FEC at Tygerberg Hospital with suspected chronic placental insufficiency. OUTCOME MEASURES The correlation coefficients indicating the strength of the relationship between the two devices and their agreement using the method of Bland and Altman. RESULTS A total of 248 patients were studied. The mean RIs of the first Doppler assessment were 0.69 (standard deviation (SD) 0.11) and 0.67 (SD 0.11) using the Vasoflow and Umbiflow respectively. The Pearson's correlation coefficient comparing the RI of the first test was 0.85. The degree of agreement between the two methods was excellent, the mean differences being very small (< 0.024) with tight confidence intervals. One hundred and ninety-four patients (78.2%) of patients remained in the same percentile category with both the Vasoflow and Umbiflow. CONCLUSIONS The accuracy of the Umbiflow has been proved. A non-significant trend towards slightly lower values needs to be considered. This could be addressed by changing the percentile cut-off to slightly lower values.
منابع مشابه
I-46: Color Doppler Assessment in IUGR
Background Fetal growth restriction is the second leading cause of perinatal morbidity and mortality. The incidence of intrauterine growth restriction (IUGR) is estimated to be approximately 5 percent in the general obstetric population. Abnormal uterine artery suggest a maternal cause for the growth restriction where as normal uterine artery Doppler studies suggest that a fetal cause. Use of u...
متن کاملI-46: Obstetrical Doppler
Accurate assessment of gestational age, fetal growth, and the detection of fetal and placental abnormalities are major benefits of sonography. Color Doppler can be used to assist in the identification of vascular architecture, detection of vascular pathology and visualization of blood flow changes associated with physiologic processes and disease states. The clinical applications of obstetrical...
متن کاملاثر بیماری کبد چرب غیرالکلی بر روی نمایههای داپلر عروق کبدی
Normal 0 false false false EN-GB X-NONE AR-SA MicrosoftInternetExplorer4 !mso]> st1":*{behavior:url(#ieooui) } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tst...
متن کاملEnd-diastolic Umbilical Artery Doppler Flow Velocity
Doppler velocity measurement has been extensively applied in prenatal diagnosis for more than two decades. Blood flow in numerous vessels has been investigated to predict fetal condition, especially in the umbilical artery [1–7]. Histopathologic studies suggest that abnormal umbilical artery Doppler velocimetry is correlated with a pathologic lesion of the placenta characterized by obliteration...
متن کاملP-247: To Evaluate The Oxytocin Effect on Maternal-Fetal Circulation during Termination of Pregnancy
Background: To evaluate the effect of oxytocin on blood circulation of fetus and uterus by Doppler ultrasound. Materials and Methods: Forty six pregnant women were assigned to receive for indication of delivery intravenous oxytocin. Doppler velocitometry before and after administration of oxytocin for umbilical,middle cerebral artery and uterine artery were performed, and Pulsatility index (PI)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde
دوره 95 1 شماره
صفحات -
تاریخ انتشار 2005