Nonproportional response of LaBr3:Ce and LaCl3:Ce scintillators to synchrotron x-ray irradiation.

نویسندگان

  • Ivan V Khodyuk
  • Pieter Dorenbos
چکیده

The nonproportional scintillation response of LaBr(3) doped with 5% Ce(3+) and of LaCl(3) doped with 10% Ce(3+) was measured using highly monochromatic synchrotron irradiation. To estimate the photon response, pulse height spectra at many finely spaced energy values between 9 and 100 keV were measured. The experiment was carried out at the X-1 beamline at the Hamburger Synhrotronstrahlungslabor (HASYLAB) synchrotron radiation facility in Hamburg, Germany. Special attention was paid to the x-ray fluorescence escape peaks as they provide us with additional information about photon response in the range 1.2-14.5 keV for LaBr(3):Ce and 2.0-11.6 keV for LaCl(3):Ce. A rapid variation of the photon response curve is observed near the lanthanum K-electron binding energy for both scintillators. A dense sampling of data was performed around this energy and those data are used to apply a method, which we call K-dip spectroscopy. This method allows us to derive the electron response curves of LaBr(3):Ce and LaCl(3):Ce down to energies as low as 0.1 keV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of LaBr3: Ce and LaCl3: Ce scintillators for spect imaging

This study aims to investigate the potential use of LaBr3:Ce and LaCl3:Ce materials in SPECT imaging. GATE Monte Carlo simulations of single-head gamma camera and a Tc point source were performed to evaluate the energy spectra, modulation transfer function (MTF) and detection efficiency. A range of Ce concentrations (0.5, 5, 10 and 15)% of LaBr3:Ce and LaCl3:Ce crystals was simulated in conjunc...

متن کامل

Pulse-shape discrimination of La halide scintillators

The bright scintillators LaCl3:Ce and LaBr3:Ce were tested for a–g pulse-shape discrimination (PSD). PSD is demonstrated for LaCl3:Ce but not for LaBr3:Ce: r 2005 Elsevier B.V. All rights reserved.

متن کامل

Lanthanum Bromide Scintillation Detector for Gamma Spectrometry Applied in Internal Radioactive Contamination Measurements

Apariţia de noi tipuri de detectori cu scintilatori anorganici LaBr3(Ce) şi LaCl3(Ce), a generat necesitatea testării lor pentru diferite aplicaţii. Ca o alternativă a detectorului NaI(Tl), utilizat, în mod tradiţional, în sistemele gama de monitorizare a I-131, în tiroidă, a fost considerat pentru caracterizare, un detector LaBr3(Ce), de dimensiuni 1.5“ x 1.5”. Rezultatele au fost evaluate, ur...

متن کامل

Response of LaBr3(Ce) scintillators to 2.5 MeV fusion neutrons.

Measurements of the response of LaBr3(Ce) to 2.5 MeV neutrons have been carried out at the Frascati Neutron Generator and at tokamak facilities with deuterium plasmas. The observed spectrum has been interpreted by means of a Monte Carlo model. It is found that the main contributor to the measured response is neutron inelastic scattering on (79)Br, (81)Br, and (139)La. An extrapolation of the co...

متن کامل

Scintillation and detection characteristics of high-sensitivity CeBr3 gamma-ray spectrometers

Crystal growth and detector fabrication technologies have reached such a state of maturity that high-quality large-volume CeBr3 scintillators can now be produced with dimensions of 2′′×2′′ and well above. We present a study of CeBr3 samples of various dimensions and show that they have a number of advantages over equivalently sized LaBr3:5%Ce for gamma-ray spectroscopy applications requiring hi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of physics. Condensed matter : an Institute of Physics journal

دوره 22 48  شماره 

صفحات  -

تاریخ انتشار 2010