A study of local electrostatic filtration and main pre-filtration on airborne and surface dust levels in air-conditioned office premises.

نویسندگان

  • B Croxford
  • K W Tham
  • A Young
  • T Oreszczyn
  • D Wyon
چکیده

The impact of electrostatic precipitation as a useful form of particulate filtration in the breathing zone is investigated in an intervention study in an air-conditioned commercial office in central London. Surface dust deposition and airborne dust levels are measured in the open plan zones of two floors--a control floor and a floor where the intervention is effected. The intervention consists of a sequence of weekly scenarios where the main pre-filters of the air-handling unit are switched between new and old filters, and where the electrostatic filters, located as uniformly as practicable on the open plan areas, are switched on or off. This 2 x 2 set of interventions is repeated over 4 cycles. It was found that the breathing zone filtration (BZF) by electrostatic precipitators reduces airborne dust significantly and appears to be more efficient in reducing smaller sized particles. No significant effect of BZF filters in reducing surface dust deposition was detected.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of gross alpha, gross beta activities and beryllium- 7 concentrations in surface air: their variation and statistical prediction model

Background: Measurement of gross , gross activities, and cosmogenic beryllium-7 (7Be) concentrations were made both daily and weekly during the years 2001- 2004 from samples of atmospheric aerosols filtered from the air at Tehran Nuclear Research Center (35 41' N) and Zahedan (28 29' N). Materials and Methods: Weekly aerosol samples were collected with the high-volume air samplers on cellul...

متن کامل

jfsv67n6p2278-2281ms20010141-ADC-TO RRD.P65

This study determined the effectiveness of components of a germicidal air-cleaning system involving filtration, electrostatic polarization, and UV light on the reduction of airborne bacteria and molds. The filter alone, filter and electrostatic polarization combined, and the filter, electrostatic polarization, and UV light were found to be effective (P < 0.05) in reducing a given concentration ...

متن کامل

Occupational and biological monitoring of workers exposed to airborne dust in Gol-e-Gohar Iron Ore mine: A Case-Control Study

Background and aims: Mining is categorized with considerable exposure to airborne contaminations. Regarding the high prevalence of diseases and the high population of workers in iron ore mines, the aim of this study was to investigate the effect of miners’ exposure to respirable dust compounds on the serum Malondialdehyde (MDA) levels. Methods: In this study, 92 non-smoker healthy workers of G...

متن کامل

Evaluation of Simultaneous Effect of Melt Filtration and Cooling Rate on Tensile Properties of A356 Cast Alloy

The combined influence of both melt filtration and cooling rate on the microstructure features and mechanical properties of A356 cast alloy was studied. A step casting model with five different thicknesses was used to obtain different cooling rates. The effect of melt filtration was studied by using of 10 and 20 ppi ceramic foam filters in the runner. Results showed that secondary dendrite arm ...

متن کامل

Massive hospital-wide bacillus outbreak related to hospital linen and construction

Results B. cereus complex constituted 164 cases (71.3%). Bacteraemia comprised 207 patient episodes (90.0%), of which 124 occurred in immunocompromised patients or those with intravascular devices. Physicians treated the organism in 68 episodes (29.5%). Environmental investigations confirmed heavy air contamination particularly within patient rooms and air conditioned wards. Dense airborne cont...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indoor air

دوره 10 3  شماره 

صفحات  -

تاریخ انتشار 2000