Problems associated with FES-standing in paraplegia.
نویسندگان
چکیده
Prolonged immobilization, such as occurs after the spinal cord injury (SCI), results in several physiological problems. It has been demonstrated that the standing posture can ameliorate many of these problems. Standing exercise can be efficiently performed by the help of functional electrical stimulation (FES). The first application of FES to a paraplegic patient was reported by Kantrowitz in 1963. It was later shown by our group that standing for therapeutic purposes can be achieved by a minimum of two channels of FES delivered to both knee extensors. The properties of the stimulated knee extensors (maximal isometric joint torque, fatiguing, and spasticity) were not found as sufficient conditions for efficient standing exercise. According to our studies, the ankle joint torque during standing is the only parameter which is well correlated to the duration of FES assisted standing. For good standing low values of the ankle joint torque are required. To minimize the ankle joint torque the lever belonging to the vertical reaction force must be decreased. Adequate alignment of the posture appears to be the prerequisite for efficient FES assisted and arm supported standing exercise. Some patients are able to assume such posture by themselves, while many must be aided by additional measures. At present, surface stimulation of knee extensors combined with some appropriately "compliant shoes" looks to be adequate choice.
منابع مشابه
Percutaneous Intramuscular FES Systems for Standing and Ambulation in Paraplegia
Average 29 1y1m 3y7m 25 Abstract-Clinical application of FES using percutaneous intramuscular electrodes in paraplegia was described. Maximum duration of continuous standing was 150 minutes and maximum distance of continuous walking was 300m with hybrid FES. Only one electrode broke (0.6%). There were 5.6% of movement of electrodes and 5.6% of superficial infections. However, the ultrafine intr...
متن کاملControl of posture with FES systems.
One of the major obstacles in restoration of functional FES supported standing in paraplegia is the lack of knowledge of a suitable control strategy. The main issue is how to integrate the purposeful actions of the non-paralysed upper body when interacting with the environment while standing, and the actions of the artificial FES control system supporting the paralyzed lower extremities. In thi...
متن کاملInverted Pendulum Standing Apparatus for Investigating Closed-Loop Control of Ankle Joint Muscle Contractions during Functional Electrical Stimulation
The restoration of arm-free standing in individuals with paraplegia can be facilitated via functional electrical stimulation (FES). In developing adequate control strategies for FES systems, it remains challenging to test the performance of a particular control scheme on human subjects. In this study, we propose a testing platform for developing effective control strategies for a closed-loop FE...
متن کاملNonlinear modelling of FES-supported standing up in paraplegia for selection of feedback sensors
This paper presents analysis of the standing–up manoeuvre in paraplegia considering the body supportive forces as a potential feedback source in FES-assisted standing–up. The analysis investigates the significance of particular feedback signals to the human body centreof-mass (COM) trajectory reconstruction. Two nonlinear empirical modeling methods are implemented (Gaussian process priors (GP) ...
متن کاملComputer simulation of FES standing up in paraplegia: a self-adaptive fuzzy controller with reinforcement learning.
Using computer simulation, the theoretical feasibility of functional electrical stimulation (FES) assisted standing up is demonstrated using a closed-loop self-adaptive fuzzy logic controller based on reinforcement machine learning (FLC-RL). The control goal was to minimize upper limb forces and the terminal velocity of the knee joint. The reinforcement learning (RL) technique was extended to m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Technology and health care : official journal of the European Society for Engineering and Medicine
دوره 7 4 شماره
صفحات -