Comparison of retinal nerve fiber layer thickness and optic disk algorithms with optical coherence tomography to detect glaucoma.
نویسندگان
چکیده
PURPOSE To compare the performance of the retinal nerve fiber layer (RNFL) thickness and optic disk algorithms as determined by optical coherence tomography to detect glaucoma. DESIGN Observational cross-sectional study. METHODS setting: Academic tertiary-care center. study population: One eye from 42 control subjects and 65 patients with open-angle glaucoma with visual acuity of > or =20/40, and no other ocular pathologic condition. observation procedures: Two optical coherence tomography algorithms were used: "fast RNFL thickness" and "fast optic disk." main outcome measures: Area under the receiver operating characteristic curves and sensitivities at fixed specificities were used. Discriminating ability of the average RNFL thickness and RNFL thickness in clock-hour sectors and quadrants was compared with the parameters that were derived from the fast optic disk algorithm. Classification and regression trees were used to determine the best combination of parameters for the detection of glaucoma. RESULTS The average visual field mean deviation (+/-SD) was 0.0 +/- 1.3 and -5.3 +/- 5.0 dB in the control and glaucoma groups, respectively. The RNFL thickness at the 7 o'clock sector, inferior quadrant, and the vertical C/D ratio had the highest area under the receiver operating characteristic curves (0.93 +/- 0.02, 0.92 +/- 0.03, and 0.90 +/- 0.03, respectively). At 90% specificity, the best sensitivities (+/-SE) from each algorithm were 86% +/- 3% for RNFL thickness at the 7 o'clock sector and 79% +/- 4% for horizontal integrated rim width (estimated rim area). The combination of inferior quadrant RNFL thickness and vertical C/D ratio achieved the best classification (misclassification rate, 6.2%). CONCLUSION The fast optic disk algorithm performs as well as the fast RNFL thickness algorithm for discrimination of glaucoma from normal eyes. A combination of the two algorithms may provide enhanced diagnostic performance.
منابع مشابه
Clinical Applications of Optical Coherence Tomography in Ophthalmology
Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases. Furtherm...
متن کاملAge-related changes in the peripheral retinal nerve fiber layer thickness
Purpose This pilot cross-sectional study aimed to determine age-related changes of the retinal nerve fiber layer (RNFL) thickness in retinal periphery by swept-source optical coherence tomography-based analysis. Methods Forty eyes of 40 healthy subjects were studied in three age groups, group 1 (20-40 years, n=15), group 2 (41-60 years, n=14), and group 3 (≥61 years, n=11). Wide-angle swept-s...
متن کاملRetinal nerve fiber layer thickness in glaucomatous and normal patients using spectral domain optical coherence tomography and standard automated perimetry-a comparative analysis
Glaucoma is characterized by a combination of structural changes in the retina and optic nerve head and functional perimetric damage. Examination and documentation of the retinal nerve fiber layer are essential for the diagnosis and monitoring of glaucoma. Spectral domain Optical coherence tomography (OCT) is a high resolution imaging device capable of obtaining reproducible retinal nerve fiber...
متن کاملRetinal Nerve Fiber Layer Imaging with Spectral-domain Optical Coherence Tomography (OCT)—A Review of the Cirrus HD-OCT
High-speed, high-resolution imaging of the retinal nerve fiber layer (RNFL) with spectral-domain optical coherence tomography (OCT) has become an essential tool for evaluation of glaucoma. The Cirrus HD-OCT (Carl Zeiss Meditec, Inc. Dublin, CA) is a spectral-domain OCT that provides visualization of the distribution pattern and measurement of RNFL abnormalities in a 6x6mm2 optic disc region. An...
متن کاملRetinal Nerve Fiber Layer Thickness Measurement Comparison Using Spectral Domain and Swept Source Optical Coherence Tomography.
PURPOSE To investigate the retinal nerve fiber layer (RNFL) thickness concordance when measured by spectral domain (SD) and swept source (SS) optical coherence tomography (OCT), and to compare glaucoma-discriminating capability. METHODS RNFL thicknesses were measured with the scan circle, centered on the optic nerve head, in 55 healthy, 41 glaucoma suspected, and 87 glaucomatous eyes. The RNF...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of ophthalmology
دوره 141 1 شماره
صفحات -
تاریخ انتشار 2006