Beam Heat Load and Pressure in the Superconducting Undulator Installed at ANKA
نویسندگان
چکیده
A superconducting undulator is installed in the ANKA (ANgstrom source KArlsruhe) storage ring since March 2005. The beam heat load and pressure on the cold bore have been analysed in the first two years of operation, during which the undulator was operated mainly with open gap. We report here on a larger statistics of beam heat load and pressure data collected in the last years with the undulator operated at different gap positions. The effect of vacuum leaks in the storage ring on the superconducting undulator operation is also described.
منابع مشابه
Can electron multipacting explain the pressure rise in a cold bore superconducting undulator?
Preliminary studies performed with the cold bore superconducting undulator installed in the ANKA (Angstrom source Karlsruhe) storage ring suggest that the beam heat load is mainly due to the electron wall bombardment. Electron bombardment can both heat the cold vacuum chamber and induce an increase in the pressure because of gas desorption. In this contribution we compare the measurements of th...
متن کاملField quality of 1.5 m long conduction cooled superconducting undulator coils with 20 mm period length
The Institute for Beam Physics and Technology (IBPT) at the Karlsruhe Institute of Technology (KIT) and the industrial partner Babcock Noell GmbH (BNG) are collaborating since 2007 on the development of superconducting undulators both for ANKA and low emittance light sources. The first full length device with 15 mm period length has been successfully tested in the ANKA storage ring for one year...
متن کاملMagnetic Measurements of the 1 . 5 M Coils of the Anka Superconducting
A 1.5 m long superconducting undulator with a period length of 15mm is planned to be installed in ANKA end 2010 to be the light source of the new beamline NANO for high resolution X-ray diffraction. The key specifications of the system are an undulator parameter K higher than 2 (for a magnetic gap of 5mm) and a phase error smaller than 3.5 degrees. In order to characterize the magnetic field pr...
متن کاملA Superconducting Short Period Undulator
Superconducting in-vacuo undulators reach higher fields at lower periods compared to permanent magnet undulators. After the first successful tests of such an undulator with beam in Mainz [1] and an analysis of the emitted radiation a team consisting of members of ACCEL and the Research Center Karlsruhe began to build a superconducting undulator for the 2.5 GeV storage ring ANKA. In this paper (...
متن کاملStatus of Colddiag: a Cold Vacuum Chamber for Diagnostics
One of the still open issues for the development of superconducting insertion devices is the understanding of the beam heat load. With the aim of measuring the beam heat load to a cold bore and the hope to gain a deeper understanding in the beam heat load mechanisms, a cold vacuum chamber for diagnostics is under construction. The following diagnostics will be implemented: i) retarding field an...
متن کامل