Phase contrast imaging: Effect of increased object-detector distances at X-ray diagnostic and megavoltage energies

نویسندگان

  • J. Loveland
  • O. Gundogdu
  • E. Morton
  • K. Wells
  • D. A. Bradley
چکیده

This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting galley proof before it is published in its final citable form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain. ABSTRACT 14 15 The effect of varying object to detector separation at constant and varying magnification has 16 been investigated at an accelerating potential of 30 kVp. Edge-contrast enhancement 17 provided by phase effects was investigated for a drinking straw and found to provide up to 18 2.52 ± 0.02 u the contrast for a PVC Heaviside step function. An optimum magnification of 19

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods

High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...

متن کامل

Quantitative in-line phase-contrast imaging with multienergy X rays.

We present a new method for quantitative nondestructive characterization of objects by x-ray phase-contrast imaging. Spatial distributions of the projected values of the complex refractive index in the sample are reconstructed by processing near-field images collected at a fixed sample-to-detector distance using a polychromatic incident beam and an energy-sensitive area detector, such as a CCD ...

متن کامل

Advantages of Monochromatic X-rays for Imaging

The contrast of X-ray imaging depends on the radiation energy and acquires its maximum value at a certain optimum energy typical for the object under investigation. Usually, higher energies result in reduced contrast, lower energies are absorbed in the object thus having a smaller probability of reaching the detector. Therefore, broad X-ray spectra contain non-optimal quanta to a large extent a...

متن کامل

Comparative study of a low-Z cone-beam computed tomography system.

Computed tomography images have been acquired using an experimental (low atomic number (Z) insert) megavoltage cone-beam imaging system. These images have been compared with standard megavoltage and kilovoltage imaging systems. The experimental system requires a simple modification to the 4 MeV electron beam from an Elekta Precise linac. Low-energy photons are produced in the standard medium-Z ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010