A video guided solution for screw insertion in orthopedic plate fixation
نویسندگان
چکیده
In orthopedic and trauma surgery, metallic plates are used for reduction and fixation of bone fractures. In clinical practice, the intra-operative planning for screw fixation is usually based on fluoroscopic images. Screw fixation is then performed on a free-hand basis. As such, multiple attempts may be required in order to achieve an optimal positioning of the fixing screws. To help the physician insert the screws in accordance to the planned position, we propose a method for screw insertion guidance. Our approach uses a small video camera, rigidly placed on the drill, and a set of small markers that are rigidly fixed on a variable angle drill sleeve. In order to investigate the achievable accuracy of our setup, we simulate the estimation of the drill bit position under two different marker arrangements, planar and 3D, and different noise levels. Furthermore, we motivate our choices for marker design and position given the limited space available for marker positioning, the requirement for accurate position estimation of the drill bit and the illumination changes that could affect the surgical site. We also describe our proposed marker detection and tracking pipeline. Our simulation results let us conclude that we can achieve an accuracy of 1 ◦ and 1 mm in the estimation of angular orientation and tip position of the drill bit respectively, provided that we have accurate marker detection.
منابع مشابه
First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw
Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...
متن کاملFirst Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw
Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...
متن کاملSubtrochanteric fracture after Garden screw fixation of subcapital fractures.
Ten cases of a complication of Garden screw fixation of subcapital fracture, namely subtrochanteric fracture through the lower screw hole, are presented. Their possible aetiology, prevention and difficulties in management are discussed. It is recommended that, during the insertion of Garden screws, care should be taken to avoid multiple attempts at passing the guide wire. If subtrochanteric fra...
متن کاملA Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملIsolated Buttress Plating of Posterior Wall Acetabular Fractures: Is it Sufficient?
Background: Conventional fixation methods of posterior wall acetabular fractures feature the use of plating and lagscrews. However, fixation of posterior wall fractures with buttress plating alone offers potential advantages by avoidingthe hardware complications related to hardware placement through the wall fragment. The purpose of this study wasto examine if buttress plating...
متن کامل