Association of biocompatible peritoneal dialysis solutions with peritonitis risk, treatment, and outcomes.
نویسندگان
چکیده
BACKGROUND AND OBJECTIVES The effect of biocompatible peritoneal dialysis (PD) solutions on PD-related peritonitis is unclear. This study sought to evaluate the relationship between use of biocompatible solutions and the probability of occurrence or clinical outcomes of peritonitis. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS The study included all incident Australian patients receiving PD between January 1, 2007, and December 31, 2010, using Australia and New Zealand Dialysis and Transplant Registry data. All multicompartment PD solutions of neutral pH were categorized as biocompatible solutions. The independent predictors of peritonitis and the use of biocompatible solutions were determined by multivariable, multilevel mixed-effects Poisson and logistic regression analysis, respectively. Sensitivity analyses, including propensity score matching, were performed. RESULTS Use of biocompatible solutions gradually declined (from 7.5% in 2007 to 4.2% in 2010), with preferential use among smaller units and among younger patients without diabetes mellitus. Treatment with biocompatible solution was associated with significantly greater overall rate of peritonitis (0.67 versus 0.47 episode per patient-year; incidence rate ratio, 1.49; 95% confidence interval [CI], 1.19 to 1.89) and with shorter time to first peritonitis (hazard ratio [HR], 1.48; 95% CI, 1.17 to 1.87), a finding replicated in propensity score-matched cohorts (HR, 1.36; 95% CI, 1.09 to 1.71). CONCLUSIONS In an observational registry study, use of biocompatible PD solutions was associated with higher overall peritonitis rates and shorter time to first peritonitis. Further randomized studies adequately powered for a primary peritonitis outcome are warranted.
منابع مشابه
The effects of biocompatible compared with standard peritoneal dialysis solutions on peritonitis microbiology, treatment, and outcomes: the balANZ trial.
BACKGROUND A multicenter, multi-country randomized controlled trial (the balANZ study) recently reported that peritonitis rates significantly improved with the use of neutral-pH peritoneal dialysis (PD) solutions low in glucose degradation products ("biocompatible") compared with standard solutions. The present paper reports a secondary outcome analysis of the balANZ trial with respect to perit...
متن کاملChanging prescribing practice in CAPD patients in Korea: increased utilization of low GDP solutions improves patient outcome.
BACKGROUND Novel, biocompatible peritoneal dialysis (PD) solutions have become available in recent years. In 2001, low glucose degradation products (GDP), neutral pH solutions became commercially available in Korea. To date, there are no reports regarding the large scale adoption of these solutions in clinical practice and regarding what, if any, impact these solutions have on patient outcomes....
متن کاملThe CARI guidelines. Evidence for peritonitis treatment and prophylaxis: the influence of peritoneal dialysis systems and solutions on the incidence of peritonitis and catheter-related infections.
a. Disconnect systems of continuous ambulatory peritoneal dialysis (CAPD) result in lower rates of peritonitis than “spike” systems and this older system should no longer be used (Evidence level 1). b. Twin bag systems have lower rates of peritonitis than Y-disconnect systems (Evidence level 1) and are recommended as the preferred CAPD technique. c. There is insufficient high level evidence to ...
متن کاملEffects of biocompatible versus standard fluid on peritoneal dialysis outcomes.
The clinical benefits of using "biocompatible" neutral pH solutions containing low levels of glucose degradation products for peritoneal dialysis compared with standard solutions are uncertain. In this multicenter, open-label, parallel-group, randomized controlled trial, we randomly assigned 185 incident adult peritoneal dialysis patients with residual renal function to use either biocompatible...
متن کاملCytotoxic Glucose Degradation Products in Fluids for Peritoneal Dialysis
During the standard heat sterilization process of the lactate–buffered peritoneal dialysis solutions, glucose (an osmotic active substance) degrades to form compounds called glucose degradation products which are cytotoxic and affect the survival of the peritoneal membrane. This case presentation is based on an observation of 224 aseptic peritonitis cases of unknown etiology. For the purpose of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical journal of the American Society of Nephrology : CJASN
دوره 8 9 شماره
صفحات -
تاریخ انتشار 2013