Exact Reconstruction of Spatially Undersampled Signals in Evolutionary Systems
نویسندگان
چکیده
We consider the problem of spatiotemporal sampling in which an initial state f of an evolution process ft = Atf is to be recovered from a combined set of coarse samples from varying time levels {t1, . . . , tN}. This new way of sampling, which we call dynamical sampling, differs from standard sampling since at any fixed time ti there are not enough samples to recover the function f or the state fti . Although dynamical sampling is an inverse problem, it differs from the typical inverse problems in which f is to be recovered from AT f for a single time T . In this paper, we consider signals that are modeled by `(Z) or a shift invariant space V ⊂ L(R).
منابع مشابه
Spatially-segmented undersampled MRI temperature reconstruction for transcranial MR-guided focused ultrasound
BACKGROUND Volumetric thermometry with fine spatiotemporal resolution is desirable to monitor MR-guided focused ultrasound (MRgFUS) procedures in the brain, but requires some form of accelerated imaging. Accelerated MR temperature imaging methods have been developed that undersample k-space and leverage signal correlations over time to suppress the resulting undersampling artifacts. However, in...
متن کاملOn Reconstruction of Signals
In this paper, we consider a signal which has been sampled synchronously with sampling frequencies equal to bandwidth (B.W) and 1.5 B.W. So, sampling is uniform and sampled signals are undersampled. Then two undersampled signals will be transmitted by two parallel transmission channels that the bandwidth of each channel is only %50 of bandwidth of the signal. Finally, a set of equations will be...
متن کاملTRZASKO AND MANDUCA: HIGHLY UNDERSAMPLED MAGNETIC RESONANCE IMAGE RECONSTRUCTION VIA HOMOTOPIC L0-MINIMIZATION 1 Highly Undersampled Magnetic Resonance Image Reconstruction via Homotopic L0-Minimization
In clinical Magnetic Resonance Imaging (MRI), any reduction in scan time offers a number of potential benefits ranging from high-temporal-rate observation of physiological processes to improvements in patient comfort. Following recent developments in Compressive Sensing (CS) theory, several authors have demonstrated that certain classes of MR images which possess sparse representations in some ...
متن کاملNonlinear GRAPPA: a kernel approach to parallel MRI reconstruction.
GRAPPA linearly combines the undersampled k-space signals to estimate the missing k-space signals where the coefficients are obtained by fitting to some auto-calibration signals (ACS) sampled with Nyquist rate based on the shift-invariant property. At high acceleration factors, GRAPPA reconstruction can suffer from a high level of noise even with a large number of auto-calibration signals. In t...
متن کاملCombining Undersampled Dithered Images
Undersampled images, such as those produced by the HST WFPC-2, misrepresent fine-scale structure intrinsic to the astronomical sources being imaged. Analyzing such images is difficult on scales close to their resolution limits and may produce erroneous results. A set of “dithered” images of an astronomical source generally contains more information about its structure than any single undersampl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- CoRR
دوره abs/1312.3203 شماره
صفحات -
تاریخ انتشار 2013