A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading.
نویسندگان
چکیده
PURPOSE In this study, standard Brånemark System implants and Brånemark TiUnite implants were evaluated regarding primary stability and placement torque. The correlation between placement torque and primary stability as well as the influence of implant design on placement torque and primary stability were examined. MATERIALS AND METHODS Twelve patients who presented bilateral loss of either maxillary lateral incisors or premolars were treated with 24 immediately loaded dental implants. Each patient received 1 standard 3.75 x 13-mm Brånemark System implant and one 3.75 x 13-mm TiUnite Mk III implant. One at a time, each implant was connected by a transducer to an Osstell machine that automatically translated a resonance frequency value for the implant into an implant stability quotient value. Osseocare equipment was used to measure the placement torque for both types of implants. RESULTS Statistical analysis showed higher mean values for standard implants in relation to placement torque and resonance frequency values. DISCUSSION There was no overall correlation between placement torque and resonance frequency values; this finding supported previous studies. CONCLUSION Stability was shown to be higher for the standard implants. Mean values of torque resistance were higher for the standard implants than for the TiUnite implants. Implant design appeared to influence primary stability and placement torque.
منابع مشابه
Immediate loading in dental implants ( A literature review )
Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...
متن کاملNovel implant design for initial stability of dental implants inserted in fresh extraction sockets: a preliminary study.
OBJECTIVES To evaluate a novel implant design for immediate implantation. This implant presents a specially designed expanded diameter midcrestal "wing" thread, which is aimed to provide added bone contact for greater insertion torque and primary stability. METHODS Mandibular premolars were extracted in 2 mongrel dogs, and immediate dental implants were inserted into the fresh extraction sock...
متن کاملDetermination of primary stability: a comparison of the surgeon's perception and objective measurements.
PURPOSE To evaluate the difference between the dental surgeon's perception of implant stability and the actual insertion torque and actual values obtained through resonance frequency analysis (RFA) during implant insertion surgery. MATERIALS AND METHODS One hundred fifty-two patients who needed one or more dental implants were selected. A total of 514 Xive implants was inserted. For all 514 i...
متن کاملImplant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications.
Osseointegrated implants for prosthetic rehabilitation of the edentulous patient show high success rates if certain preconditions are fulfilled. Implant stability plays a critical role for a successful critical outcome since short implants and implants placed in soft bone are more prone to failure (13, 49). In the original protocols for implant placement, primary implant stability was ensured b...
متن کاملSuccess rate of immediate loading of single OPILS implants of Neo-Dent system
Success rate of immediate loading of single OPILS implants of Neo-Dent system Dr. SH. Namjoy Nik * - Dr. SH. Shahab ** - Dr. M. Mohammad Poor*** - Dr. A. Balooch*** *- Assistant Professor of Oral and Maxillofacial Surgery Dept. - Faculty of Dentistry – Shahed University. **- Assistant Professor of Oral Radiology Dept. Faculty of Dentistry – Shahed University. ***- Dentist. Background and Aim: I...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 19 4 شماره
صفحات -
تاریخ انتشار 2004