Tissue dielectric constant (TDC) measurements as a means of characterizing localized tissue water in arms of women with and without breast cancer treatment related lymphedema.

نویسندگان

  • H N Mayrovitz
  • D N Weingrad
  • S Davey
چکیده

Quantitative measurements to detect lymphedema early in persons at-risk for breast cancer (BC) treatment-related lymphedema (BCRL) can aid clinical evaluations. Since BCRL may be initially manifest in skin and subcutis, the earliest changes might best be detected via local tissue water (LTW) measurements that are specifically sensitive to such changes. Tissue dielectric constant (TDC) measurements, which are sensitive to skin-to-fat tissue water, may be useful for this purpose. TDC differences between lymphedematous and non-lymphedematous tissue has not been fully characterized. Thus we measured TDC values (2.5 mm depth) in forearms of three groups of women (N = 80/group): 1) healthy with no BC (NOBC), 2) with BC but prior to surgery, and 3) with unilateral lymphedema (LE). TDC values for all arms except LE affected arms were not significantly different ranging between 24.8 ± 3.3 to 26.8 ± 4.9 and were significantly less (p < 0.001) as compared to 42.9 ± 8.2 for LE affected arms. Arm TDC ratios, dominant/non-dominant for NOBC, were 1.001 ± 0.050 and at-risk/ contralateral for BC were 0.998 ± 0.082 with both significantly less (p < 0.001) than LE group affected/control arm ratios (1.663 ± 0.321). These results show that BC per se does not significantly change arm LTW and that the presence of BCRL does not significantly change LTW of non-affected arms. Further, based on 3 standard deviations of measured arm ratios, our data demonstrates that an at-risk arm/contralateral arm TDC ratio of 1.2 and above could be a possible threshold to detect pre-clinical lymphedema. Further prospective measurement trial are needed to confirm this value.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental and Analytical Comparisons of Tissue Dielectric Constant (TDC) and Bioimpedance Spectroscopy (BIS) in Assessment of Early Arm Lymphedema in Breast Cancer Patients after Axillary Surgery and Radiotherapy.

BACKGROUND Early diagnosis of breast cancer treatment-related lymphedema (BCRL) is of great importance for longstanding treatment results. Tissue dielectric constant (TDC) and bioimpedance spectroscopy (BIS) both have a potential for early diagnosis, but have not been compared. METHODS AND RESULTS One hundred women, treated for breast cancer with breast surgery, axillary dissection, and radio...

متن کامل

Local tissue water in at-risk and contralateral forearms of women with and without breast cancer treatment-related lymphedema.

BACKGROUND Quantitative measurements to help detect incipient or latent lymphedema in patients at risk for breast cancer treatment-related lymphedema (BCRL) are potentially useful supplements to clinical assessments. Suitable measurements for routine use include arm volumes, arm bioimpedance, and local tissue water (LTW) determined from the tissue dielectric constant (TDC). Because BCRL initial...

متن کامل

Role of handedness on forearm skin tissue dielectric constant (TDC) in relation to detection of early-stage breast cancer-related lymphedema.

skin tissue dielectric constant (TDC) measurements help assess local skin water to detect incipient early-stage lymphedema subsequent to breast cancer treatment-related lymphedema. However, presurgery measurements are not always obtained and assessments for evolving lymphedema are only made after surgery. Thus, subsequent TDC assessments may be biased in an unknown way dependent on a patient's ...

متن کامل

Localized tissue water changes accompanying one manual lymphatic drainage (MLD) therapy session assessed by changes in tissue dielectric constant inpatients with lower extremity lymphedema.

Previous reports described the utility of assessing local tissue water via tissue dielectric constant (TDC) measurements. Our goal was to determine the suitability of this method to evaluate lymphedema changes. For this purpose, we measured changes in TDC produced by one MLD treatment in 27 legs of 18 patients with lower extremity lymphedema. TDC values were measured to a depth of 2.5 mm at the...

متن کامل

Patterns of temporal changes in tissue dielectric constant as indices of localized skin water changes in women treated for breast cancer: a pilot study.

BACKGROUND Our goal was to characterize temporal patterns of skin Tissue Dielectric Constant (TDC) as a foundation for possible TDC use to detect and quantify lymphedema. Although limb volumes and bioimpedance analysis (BIA) are used for this purpose, potential TDC-method advantages are that it can be done in about 10 seconds at any body site to depths from 0.5 to 5.0 mm below the epidermis. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lymphology

دوره 47 3  شماره 

صفحات  -

تاریخ انتشار 2014