The Effectiveness of Real-Time Feedback with an Audible Pulse: A Preliminary Study in Renal Doppler Ultrasonography

نویسندگان

  • Min Hee Lee
  • Hae Kyung Lee
  • Seo-Youn Choi
  • Boem Ha Yi
چکیده

PURPOSE The effectiveness of real-time feedback using an audible pulse in renal Doppler ultrasonography was evaluated. METHODS This study was approved by the institutional review board of our hospital. Written informed consent was provided by all volunteers at enrollment. The 26 healthy volunteers enrolled in this study underwent Doppler ultrasound of both kidneys using audible and inaudible pulses in randomized order and at 1-week intervals. Doppler waveforms were obtained at the interlobar or arcuate arteries using a 2-mm Doppler gate. Each session was considered complete when reproducible waveforms were obtained for 5 s in three predefined regions of the kidney. The scan times needed to obtain waveforms of the right and left kidneys were recorded separately. Measurements were compared using a paired t-test and a two-sample Wilcoxon rank-sum test. RESULTS The total recorded Doppler sonography scan time for each kidney ranged from 33 to 146 s. The mean scan time was 56.83 s (right, 58.19 s; left, 55.46 s) in the audible session and 72.58 s (right, 72.08 s; left, 73.08 s) in the inaudible session. The scan times were significantly shorter in the audible than inaudible session (p<0.001), whereas the difference in the scan times between the right and left kidneys was not significant. The order of the sessions had no effect on the total scan time. CONCLUSION Real-time feedback using an audible pulse may encourage patient cooperation during breath-holding and can shorten the time needed to perform Doppler ultrasonography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Doppler ultrasonography in children with acute pyelonephritis in diagnosis of renal scar compared to DMSA scintigraphy

Background: Urinary tract infection (UTI) is one of the most important pediatric health problems, which is occasionally associated with irreversible renal damage. Dimercapto-succinic acid (DMSA) scan is a diagnostic standard for the renal scar. Doppler ultrasonography (D.S) has been considered as a less invasive method. The purpose of this study was to determine the sensitivity and specificity ...

متن کامل

Pulse Doppler Analysis in External Ophthalmic and the Long Ciliary Ophthalmic Arteries in the Cat

Objective- Analysis of the PSV (peak systolic velocity), EDV (end diastolic velocity) and RI (Resistant Index) in external ophthalmic and the long ciliary ophthalmic arteries in the cat by pulse Doppler. Design- Descriptive study Animals- 12 short haired “Tomcats” weighted about 3.9± 0.9 Kg no e general and optic disease in clinical, paraclinical and ophthalmoscopic examinations. Pr...

متن کامل

بررسی حدود طبیعی معیارهای سونوگرافی داپلر در شرایین کلیویEvaluation of Normal Doppler Indices in Renal Arteries

    Background & Aim: Doppler ultrasonography is important in diagnosis of renal diseases by demonstrating vascular anatomy and hemodynamics. There is not any fix doppler indices in all of the references and it is suggested that each center should have its own standards. Also it is proved that biologic indices are not the same in different societies. The present study was performed on normal Ir...

متن کامل

بررسی نقش یافته های داپلر سونوگرافی در تعیین شانس تعبیه ، میزان شکست و قابل دستیابی شدن فیستول شریانی وریدی در بیماران همودیالیزی کاندید تعبیه فیستول شریانی وریدی

Background: Arteriovenous fistula is an important method for hemodialysis and prediction of fistula function and failure rate and access is crucial. This study was performed to determine the association between Doppler ultrasonography findings with function and failure and access rate of fistula. Methods: In this observational comparative cross-sectional study, out of 108 patients requiring fi...

متن کامل

Pathological and Doppler Ultrasonographic Study of Kidney Hemodynamic Response in Saffron (Crocus Sativua) Pretreated Rats

Objective-  To evaluate kidney hemodynamic response including blood flow velocity in segmental arteries shortly after administration of various dose of saffron extract (10, 40 and 90 mg/kg).   Design- Technical assessment, experimental study.   Animals- 20 healthy male Sprague-Dawley rats.   Procedures- In this study, using a real-time pulsed doppler analysis, kidney hemodynamic response inc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016