Cclii. Some Observations on the Estimation of Muscle

نویسنده

  • R. H. WATSON
چکیده

N-UMEROUS observations in the past decade, culminating in the isolation of the crystalline material and the study of its properties by Theorell [1932; 1934, 1, 2, 3, 4] have established the identity of muscle haemoglobin. Attempts to estimate it, however, have for the most part been concerned with it less as a chemical identity than as that haemoglobin which remains behind after perfusing the tissue apparently free of blood. The most notable of these is that of Whipple [1926]. Though his estimations show consistency, it is not certain that they represent the actual concentrations of muscle haemoglobin. There is the possibility that some haemoglobin has been lost in the perfusion of the tissue and uncertainty both as to whether there is an equal distribution of muscle haemoglobin between the tissue and the extracting fluid and as to the actual volume of the tissue. Further there is the possibility of other acid haematin compounds being extracted from the cell and introducing error into the subsequent acid haematin determination. Finally the conclusions drawn from the colorimetric comparison of the carboxy-compounds may be incorrect, for Theorell [1934, 2] has since shown that the light absorptions by the carboxyhaemoglobins of muscle and blood are different. In this paper is reported an attempt to develop a method for a more exact estimation by extracting the whole of the haemoglobin from the unperfused tissue and by determining the relative concentrations of muscle and blood haemoglobin in the extract from the mean position of the oc-band of the oxyhaemoglobin compounds as observed with the Hartridge reversion spectroscope and the determination of the total concentration of haemoglobin spectrophotometrically. Some observations on Whipple's [1926] method of extraction, the outcome of a comparison of it with the method developed, are also reported. Shenk et al. [1934] describe a method somewhat similar in principle. These authors are to be commended for their heroic effort in perfusing an ox. There exist, however, discrepancies between the spectrophotometric constants obtained with their extract of the perfused tissue and those obtained by Theorell [1934, 2] with the crystalline horse muscle haemoglobin. Though these may be due to the difference in the source of the haemoglobin, it has been the experience of the author that it is extremely difficult to perfuse a tissue entirely free of blood haemoglobin. Further, the same uncertainty as to the distribution of the haemoglobin between the tissue and the extracting fluid etc., exists as in Whipple's [1926] method. 6

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative Assessment of Muscle Fatigue for FES Research Studies

Background: Muscle fatigue is an important issue in neuromuscular rehabilitation. Better control of this phenomenon would result in better prevention of its consequent physiological damages.Objective: To provide a mathematical representation of muscle fatigue as a function of time.Methods: We conducted this study by combining the EMG-based estimation methods of muscle activation with the availa...

متن کامل

Retrieving Three Dimensional Displacements of InSAR Through Regularized Least Squares Variance Component Estimation

Measuring the 3D displacement fields provide essential information regarding the Earth crust interaction and the mantle rheology. The interferometric synthetic aperture radar (InSAR) has an appropriate capability in revealing the displacements of the Earth’s crust. Although, it measures the real 3D displacements in the line of sight (LOS) direction. The 3D displacement vectors can be retrieved ...

متن کامل

Iranian Permanent GPS Network Receivers Differential Code Biases Estimation Using Global Ionospheric Maps

Measurements of the dual frequency Global Positioning System (GPS) receivers can be used to calculate the electron density and the total electron content (TEC) of the ionosphere layer of the Earth atmosphere. TEC is a key parameter for investigating the ongoing spatial and temporal physical process of the ionosphere. For accurate estimation of TEC from GPS measurements, GPS satellites and GPS r...

متن کامل

Detection of Outliers and Influential Observations in Linear Ridge Measurement Error Models with Stochastic Linear Restrictions

The aim of this paper is to propose some diagnostic methods in linear ridge measurement error models with stochastic linear restrictions using the corrected likelihood. Based on the bias-corrected estimation of model parameters, diagnostic measures are developed to identify outlying and influential observations. In addition, we derive the corrected score test statistic for outliers detection ba...

متن کامل

Distributed Incremental Least Mean-Square for Parameter Estimation using Heterogeneous Adaptive Networks in Unreliable Measurements

Adaptive networks include a set of nodes with adaptation and learning abilities for modeling various types of self-organized and complex activities encountered in the real world. This paper presents the effect of heterogeneously distributed incremental LMS algorithm with ideal links on the quality of unknown parameter estimation. In heterogeneous adaptive networks, a fraction of the nodes, defi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005