Distribution of nerve endings in human distal interphalangeal joint and surrounding structures.
نویسندگان
چکیده
PURPOSE To examine the distribution of encapsulated nerve endings called mechanoreceptors in the human distal interphalangeal (DIP) joint and surrounding structures. METHODS We processed 12 right index finger DIP joints and surrounding structures from fresh cadavers for immunohistochemistry of the anti-protein gene product 9.5 (PGP9.5) and silver staining to detect encapsulated nerve endings. Serial transverse sections were cut throughout the whole specimen and divided into 3 regions along the longitudinal axis: distal, middle, and proximal. Each of the transverse sections was partitioned into dorsal capsule (DC), radial capsule (RC), ulnar capsule (UC), volar plate (VP), and radial and ulnar assemblage nuclei (RAN and UAN); the RAN and UAN are located on both the radial and ulnar side of the VP. The C3 pulley contained the proximal region of the RAN and UAN, whereas the A5 pulley contained the middle and distal. The accessory collateral ligament contained all the regions of the RAN and UAN. We analyzed and compared the density of encapsulated nerve endings among the 18 different regions. RESULTS According to the modified Freeman and Wyke classification, we identified type I (eg, Ruffini-like endings) and type II (eg, Pacini-like endings) nerve endings. The density of type II nerve endings in the proximal region of the RAN and UAN was considerably higher than that in the proximal region of the VP, RC, UC and DC, and that in the proximal region of the VP, RC, UC, and DC, respectively. CONCLUSIONS Our examination of the distribution of type I and type II nerve endings provides new information on the sensory systems of the DIP joints and surrounding structures.
منابع مشابه
Evaluation of Palmar Digital Nerve Block and Distal Interphalangeal Joint Analgesia in Lame Horses Associated with Hoof Pain due to Sidebone Fracture
Objective- To determine if the pain of the third phalanx due to sidebone fracture in horses can be attenuated by analgesia of the distal interphlangeal joint and palmar digital nerve block. Design- Clinical study. Animals- Seven horses with unilateral forelimb lameness associated with hoof pain due to sidebone fracture. Procedures- Seven mix breed show jumping horses were selected from hor...
متن کاملA Comparative Study on Tendon Transfer Surgery in Patients with Radial Nerve Palsy
BACKGROUND Lesions in peripheral nerves are highly prevalent in the upper extremity. The present study compares different tendon transfer surgeries in patients with radial nerve palsy. METHODS Fifty patients with radial nerve palsy were randomly selected among patients who referred to Tehran 15th Khordad Hospital during 2006-2011. They were divided into two groups of 17 and 33 subjects. Sing...
متن کاملA Comparative Study on Tendon Transfer Surgery in Patients with Radial Nerve Palsy
BACKGROUND Lesions in peripheral nerves are highly prevalent in the upper extremity. The present study compares different tendon transfer surgeries in patients with radial nerve palsy. METHODS Fifty patients with radial nerve palsy were randomly selected among patients who referred to Tehran 15(th) Khordad Hospital during 2006-2011. They were divided into two groups of 17 and 33 subjects. Sin...
متن کاملExtension block pining for treatment of bony mallet finger
Abstract Background: The goal of this report is to show our results with extension block technique for treatment of mallet fracture. The indications for this technique were the presence of a large bone fragment, and palmar subluxation. Methods: We retrospectively assessed the results of treatment in 14 mallet fractures which have been treated by extension block technique to determine the ra...
متن کاملAnterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture
We describe the case of a patient with distal radius fracture who became unable to flex the distal interphalangeal joint of the index finger after internal fixation using a volar locking plate. There was palpable crepitus with active thumb motion, and wrist radiographs showed prominence of the volar plate at the watershed line. Therefore, our initial diagnosis was plate-induced closed rupture o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of hand surgery
دوره 36 3 شماره
صفحات -
تاریخ انتشار 2011