Technology for automated, rapid, and quantitative PCR or reverse transcription-PCR clinical testing.
نویسندگان
چکیده
BACKGROUND PCR-based assays can improve clinical care, but they remain technically demanding and labor-intensive. We describe a new instrument, the GeneXpert, that performs automated nucleic acid isolation, reverse transcription, and fluorescence-based quantitative PCR in approximately 35 min. METHODS Yield and integrity of RNA isolated on the GeneXpert were compared with Qiagen-based extraction for parallel samples (5-microm frozen tissue sections). The reproducibility of automated RNA isolation, reverse transcription, and quantitative PCR was determined by replicate (n = 10) analysis of 10 tissues, using duplex (target and endogenous control) reverse transcription-PCR reactions for two gene combinations. The GeneXpert was then used to perform rapid analysis of lymph nodes from melanoma, breast cancer, and lung cancer patients and analysis of melanoma metastatic to the lung, primary lung adenocarcinoma, and healthy lung tissue. RESULTS On the GeneXpert, RNA was recovered in slightly over 6 min, and the yield was approximately 70% of that from parallel Qiagen reactions. The RNA integrity was comparable to that of Qiagen-isolated RNA as determined by gel electrophoresis. For the melanoma samples, the 95% prediction interval for the deltaCt for a new measurement was +/-1.54 cycles, and for breast cancer samples, the interval for a newly observed deltaCt was +/-1.40 cycles. GeneXpert assays successfully detected the presence of metastatic melanoma, breast cancer, and lung cancer in lymph nodes and also differentiated among metastatic melanoma, lung adenocarcinoma, and healthy lung. CONCLUSIONS RNA yield and integrity on the GeneXpert are comparable to benchtop methods. Reproducibility of the GeneXpert data is similar to that seen with manual methods in our hands but may need improvement for some applications. The GeneXpert can perform RNA isolation, reverse transcription, and quantitative PCR in approximately 35 min and could therefore be used for intraoperative testing when applicable.
منابع مشابه
Development of Multiplex Reverse Transcription-Polymerase Chain Reaction for Simultaneous Detection of Influenza A, B and Adenoviruses
Background and objective:Millions of people in developing countries lose their lives due to acute respiratory infections, such as Influenza A & B and Adeno viruses. Given the importance of rapid identification of the virus, in this study the researchers attempted to design a method that enables detection of influenza A, B, and adenoviruses, quickly and simultaneously. ...
متن کاملDevelopment and Evaluation of Real-Time Reverse Transcription Polymerase Chain Reaction Test for Quantitative and Qualitative Recognition of H5 Subtype of Avian Influenza Viruses
Avian influenza viruses (AIV) affect a wide range of birds and mammals, cause severe economic damage to the poultry industry, and pose a serious threat to humans. Highly pathogenic avian influenza viruses (HPAI) H5N1 were first identified in Southeast Asia in 1996 and spread to four continents over the following years. The viruses have caused high mortality in chickens and various bird species ...
متن کاملA Reverse transcription-PCR assay for detection of type A influenza virus and differentiation of avian H7 subtype
Abstract : Avian influenza virus (AIV) infection is a major cause of influenza mortality in birds and can cause human mortality and morbidity. Although the risk of infection with avian influenza virus (AIV) is generally low for most people, the pathogenic virus can cross the species barrier and acquires the ability to infect and be transmitted among the human population; therefore the ra...
متن کاملDiagnostic value of reverse transcription-PCR for detection of cytomegalovirus pp67 in samples from solid-organ transplant recipients.
We evaluated a highly sensitive quantitative real-time one-step reverse transcription-PCR (RT-PCR) for detection of human cytomegalovirus pp67 transcripts in monitoring of solid-organ transplant recipients. Results were compared with those of pp65 antigen testing and quantitative DNA-PCR. Due to a low clinical sensitivity, the pp67 RT-PCR was not able to replace these assays.
متن کاملExpression of HER2 and the coamplified genes GRB7 and MLN64 in human breast cancer: quantitative real-time reverse transcription-PCR as a diagnostic alternative to immunohistochemistry and fluorescence in situ hybridization.
PURPOSE Accurate testing of HER2 is centrally important for breast cancer therapy and prognosis. Immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH) are current standard testing methods. As a potential alternative for assessment of HER2, we explored quantitative real-time reverse transcription-PCR (RT-PCR), a fast and inexpensive method yielding quantitative results insensi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 51 5 شماره
صفحات -
تاریخ انتشار 2005