Non-linear dielectric spectroscopy of microbiological suspensions

نویسندگان

  • Ernesto F Treo
  • Carmelo J Felice
چکیده

BACKGROUND Non-linear dielectric spectroscopy (NLDS) of microorganism was characterized by the generation of harmonics in the polarization current when a microorganism suspension was exposed to a sinusoidal electric field. The biological nonlinear response initially described was not well verified by other authors and the results were susceptible to ambiguous interpretation. In this paper NLDS was performed to yeast suspension in tripolar and tetrapolar configuration with a recently developed analyzer. METHODS Tripolar analysis was carried out by applying sinusoidal voltages up to 1 V at the electrode interface. Tetrapolar analysis was carried on with sinusoidal field strengths from 0.1 V cm(-1) to 70 V cm(-1). Both analyses were performed within a frequency range from 1 Hz through 100 Hz. The harmonic amplitudes were Fourier-analyzed and expressed in dB. The third harmonic, as reported previously, was investigated. Statistical analysis (ANOVA) was used to test the effect of inhibitor an activator of the plasma membrane enzyme in the measured response. RESULTS No significant non-linearities were observed in tetrapolar analysis, and no observable changes occurred when inhibitor and activator were added to the suspension. Statistical analysis confirmed these results.When a pure sinus voltage was applied to an electrode-yeast suspension interface, variations higher than 25 dB for the 3rd harmonic were observed. Variation higher than 20 dB in the 3rd harmonics has also been found when adding an inhibitor or activator of the membrane-bounded enzymes. These variations did not occur when the suspension was boiled. DISCUSSION The lack of result in tetrapolar cells suggest that there is no, if any, harmonic generation in microbiological bulk suspension. The non-linear response observed was originated in the electrode-electrolyte interface. The frequency and voltage windows observed in previous tetrapolar analysis were repeated in the tripolar measurements, but maximum were not observed at the same values. CONCLUSION Contrary to previous assertions, no repeatable dielectric non-linearity was exhibited in the bulk suspensions tested under the field and frequency condition reported with this recently designed analyzer. Indeed, interface related harmonics were observed and monitored during biochemical stimuli. The changes were coherent with the expected biological response.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polarizability and Hyperpolarizability of Schiff Base Salen-H2 as Judged as UV-vis Spectroscopy and Simulation Analysis

The aim of the present study was to evaluate the properties of linear andnonlinear optics of the Schiff base Salen. Crystal structure of nanoparticles wasdetermined by a Bruker make diffractometer, Cu-K X-rays of wavelength (=1.5406Å). The XRD patterns were recorded in the 2 range of 10–90o with a step width of 0.02s-1. The UV-Vis Spectra recorded on a computerized double - beam Shimadzu 255...

متن کامل

Correcting the polarization effect in very low frequency dielectric spectroscopy

Polarization impedance appears at the interface between electrodes and ionic solutions and is a major source of errors in dielectric spectroscopy measurements. This work presents a simple, robust and automated methodology for measuring and analysing the polarization impedance of non-dispersive electrolytes, with a focus on the very low frequency domain from 1 Hz and up. The accuracy of the meth...

متن کامل

Vibration of Road Vehicles with Non linear Suspensions

In order to investigate the effects of non-linear springs in vibrating behavior of vehicles, the independent suspension of conventional vehicles could be modeled as a non-linear single degree of freedom system. The equation of motion for the system would be a non-linear third order ordinary differential equation, when considering the elasticity of rubber bushings in joints of shock absorber. It...

متن کامل

Single Cell Dielectric Spectroscopy in a Micro-channel

We propose the idea of single cell dielectric spectroscopy for future clinical applications such as cell therapy and regenerative medicine. The structure of the microfluidic device is carefully designed to suppress the influence of electrode polarization on the dielectric spectra of single cells. Beads of uniform size distribution is used to determine the detection limit. As feasibility tests f...

متن کامل

Dielectric spectroscopy of Anabaena 7120 protoplast suspensions.

The dielectric spectroscopy of Anabaena 7120 protoplast suspensions has been investigated over the frequency range of 40 Hz-110 MHz. The protoplast suspensions showed a complicated dielectric dispersion consisting of at least four distinct sub-dispersions with the increasing frequencies due to the Maxwell-Wagner interfacial polarization. The double-shell model, in which an equivalent shell of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioMedical Engineering OnLine

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2009