Three-dimensional digital angiography: new tool for simultaneous three-dimensional rendering of vascular and osseous information during rotational angiography.

نویسندگان

  • Philippe Gailloud
  • Satoru Oishi
  • Jeffrey Carpenter
  • Kieran J Murphy
چکیده

Three-dimensional (3D) digital subtraction angiography (DSA) is the latest development in the neurovascular imaging armamentarium. 3D-DSA combines the anatomic resolution of DSA with 3D visualization abilities previously offered by only CT or MR angiography. 3D-DSA provides more detailed information than does DSA alone in the evaluation of neurovascular lesions, such as cerebral aneurysms. However, the inability of 3D-DSA to simultaneously image osseous and vascular structures is noted as a weakness of this technique compared with CT angiography. We describe a new 3D digital angiography reconstruction algorithm that allows the concurrent display of the cerebral vasculature and the osseous landmarks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional fusion digital subtraction angiography: new reconstruction algorithm for simultaneous three-dimensional rendering of osseous and vascular information obtained during rotational angiography.

This report describes three-dimensional (3D) fusion digital subtraction angiography (FDSA), a new algorithm for rotational angiography that combines reconstructions of the blood vessels and the osseous frame in a single 3D representation. 3D-FDSA is based on separate reconstructions of the mask and contrast sequences of the rotational acquisition. The two independent 3D data sets (3D-bone and 3...

متن کامل

Large-cohort comparison between three-dimensional time-of-flight magnetic resonance and rotational digital subtraction angiographies in intracranial aneurysm detection.

BACKGROUND AND PURPOSE The value of MR angiography varies in diagnosis of intracranial aneurysms due to the difference of equipment and imaging technique. This study was to compare the effectiveness of 3-dimensional time-of-flight MR angiography at 3 T and rotational digital subtraction angiography, both with volume rendering (VR), in detecting intracranial aneurysms. METHODS One hundred thir...

متن کامل

Role of Three-Dimensional Rotational Angiography in the Treatment of Spinal Dural Arteriovenous Fistulas

Spinal dural arteriovenous fistulas (AVFs), being the most commonly encountered spinal vascular malformations, result in considerable morbidity with progressive spinal cord symptoms. A selective spinal digital subtraction angiography (DSA) is needed to confirm the diagnosis, to better evaluate the fine vascular structures and to plan therapy. With the introduction of three-dimensional rotationa...

متن کامل

Clinical usefulness of unsubtracted 3D digital angiography compared with rotational digital angiography in the pretreatment evaluation of intracranial aneurysms.

BACKGROUND AND PURPOSE Three-dimensional digital subtraction angiography (DSA) is useful as a supplement to 2D DSA in the pretreatment evaluation of intracranial aneurysms. However, the clinical efficacy of 3D digital angiography (DA) that is generated from unsubtracted rotational images has not been established. The purpose of this study was to assess whether 3D DA provides additional useful i...

متن کامل

Application of live 3D tools in vascular interventional radiology

An accurate morphological assessment of blood vessels and their relationship with interventional devices is essential in the management of vascular lesions, and digital subtraction angiography (DSA) has had a central role in the deployment of interventional procedures. The introduction of three-dimensional rotational angiography (3D RA) and flat panel detector technology has further contributed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 25 4  شماره 

صفحات  -

تاریخ انتشار 2004