Early and Midterm Major Adverse Cardiac Events in Patient With Saphenous Vein Graft Using Direct Stenting or Embolic Protection Device Stenting

نویسندگان

  • Mohammadali Sadr-Ameli
  • Hossein Mousavi
  • Mona Heidarali
  • Mohsen Maadani
  • Yones Ghelich
  • Behshid Ghadrdoost
چکیده

BACKGROUND The treatment of an occluded saphenous vein graft (SVG) with percutaneous coronary intervention may encounter major adverse cardiac events (MACE). MACE rates have been reduced significantly by using the embolic protection device (EPD). OBJECTIVES The aim of this study was to clarify the risks and the benefits of embolic protection devices. PATIENTS AND METHODS In a prospective, non-randomized observational study, patients aged 33 to 85 years old who underwent elective percutaneous coronary intervention due to SVG stenosis at our tertiary care center were enrolled between 2009 and 2011. The incidence rates of adverse events, including MACE, were obtained during the patients' hospitalization and at 30-day and 6-month follow-up. MACE included death, Q-wave and non-Q-wave myocardial infarction, in-stent thrombosis, target lesion revascularization, and target vessel revascularization. RESULTS From 150 patients enrolled to the study, 128 (85.3%) patients underwent direct stenting and the rest underwent the EPD procedure. In-hospital MACE occurred in 17.2% of the patients in the direct stenting group versus only 9.1% in the EPD group (P = 0.530). MACE incidence was gradually increased at one and 6-month follow-up periods in the direct stenting group (19.5% and 21.9%, respectively), and remained unchanged in the EPD group (9.1% at six-month follow-up). Multivariate logistic regression model showed that the stenting procedure type could not predict early and midterm MACE with the presence of baseline characteristics as cofounders. CONCLUSIONS Despite the considerable lower early and midterm MACE rates, numerically following the EPD procedure compared to direct stenting, the difference in the MACE rates between the two groups was not significant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES

Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...

متن کامل

Embolic protection during saphenous vein graft intervention using a second-generation balloon protection device: results from the combined US and European pilot study of the TriActiv Balloon Protected Flush Extraction System.

BACKGROUND Stent placement in saphenous vein bypass grafts is associated with a high incidence of myonecrosis usually resulting from embolization of thrombus and friable atheroma. Embolic protection devices reduce the incidence of adverse events after vein graft stenting. However, first-generation balloon occlusion systems are still associated with a 10% incidence of periprocedural adverse even...

متن کامل

Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts.

BACKGROUND Stents provide effective treatment for stenotic saphenous venous aorto-coronary bypass grafts, but their placement carries a 20% incidence of procedure-related complications, which potentially are related to the distal embolization of atherosclerotic debris. We report the first multicenter randomized trial to evaluate use of a distal embolic protection device during stenting of such ...

متن کامل

Embolic protection with filtering or occlusion balloons during saphenous vein graft stenting retrieves identical volumes and sizes of particulate debris.

BACKGROUND Distal embolization of plaque particulate liberated during stenting may cause periprocedural complications. The number, size, and volume of debris released during stenting, however, have not been quantified, rendering embolic protection approaches empiric. We used a novel method of microparticle size assessment to measure volume and characterize individual sizes of particles captured...

متن کامل

Long-term outcomes of saphenous vein graft stenting compared with native coronary artery stenting in patients with previous coronary artery bypass graft surgery.

OBJECTIVE Our main objective was to compare the in-hospital and long-term outcomes of saphenous vein graft stenting and native coronary artery stenting in patients with previous coronary artery bypass grafting. METHODS We studied 127 patients who had prior coronary artery bypass; they were divided in two groups, according to the kind of percutaneous coronary intervention performed. The first ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2014