First Density Profile Measurements Using FMCW Reflectometry on JET
نویسندگان
چکیده
منابع مشابه
Phase Noise Considerations in Coherent Optical FMCW Reflectometry
phase noise, coherent reflectometry, FMCW, Rayleigh backscattering, fiberoptic interferometry An analysis of coherent optical FMCW is presented. It shows the limitations imposed on measurements of discrete reflections and of Rayleigh backscattering due to phase noise originating in the finite coherence length of the optical source. The dependence of the range for accurate measurements on partic...
متن کاملDensity profile measurements with X-mode lower cut-off reflectometry in ASDEX Upgrade.
Despite the fact that density profile measurements using X-mode lower cut-off reflectometry are foreseen to be used on ITER, little or no experience is available within the reflectometry community and to our knowledge no results on this subject have been published so far. In ASDEX Upgrade the multichannel broadband reflectometer is equipped with b...
متن کاملReconstruction of the turbulence radial profile from the reflectometry phase root mean square measurements
Simple expressions allowing estimation of the turbulent density perturbation from the reflectometry phase root mean square (r.m.s.) measurements and accounting for the turbulence correlation length are given. The numerical procedure for precise turbulence radial profile reconstruction for different turbulence wave number spectra and both O-mode and X-mode reflectometry is proposed. It is valida...
متن کاملOngoing work towards real-time reflectometry density profile measurements on ASDEX Upgrade
Previous studies performed in ASDEX Upgrade ELMy H-mode regimes (Santos et al. [2003]), ITER reference scenario, have shown that O-mode FM-CW reflectometry should meet the accuracy required on ITER for using reflectometry for position control purposes. This application, however, requires the development of robust unsupervised methods to evaluate the density profiles in real time. To allow a sta...
متن کاملExtended-Range High-Resolution FMCW Reflectometry by Means of Electronically Frequency-Multiplied Sampling Signal Generated from Auxiliary Interferometer
High-resolution FMCW reflectometry is often realized by sampling the beat signal with a clock signal generated from an auxiliary interferometer. The drawback of this system is that the measurement range is limited to less than half of the optical path difference of the auxiliary interferometer to satisfy the Sampling theorem. We propose and demonstrate a method to extend the measurement range o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -