PURPOSE To assess the corneal swelling response to two myopic correction corneal refractive therapy (CRT) lenses of varying Dk/t values, worn for a single night. Change in thickness of the total cornea, stroma, and epithelium was measured across the horizontal meridian using optical coherence tomography (OCT). METHODS In this double-masked, randomized study, twenty subjects wore a CRT design lens in each eye, manufactured from Menicon Z (MenZ; Dk/t = 91) and Equalens II (EqII; Dk/t = 47) materials. Baseline corneal thickness was measured centrally and at four points either side of the central cornea using OCT, the night before sleeping at the Centre for Contact Lens Research. The next morning, lenses were removed, and thickness measurements were repeated 1, 3, 6, and 12 h after removal. RESULTS On lens removal, the MenZ eye had central and paracentral corneal swelling (mean +/- SD) of 4.1 +/- 2.0% and 5.6 +/- 2.4%, and the EqII eye had 5.8 +/- 2.6% and 7.0 +/- 2.6%. These values were significantly different from baseline (ReANOVA; p < 0.001) and were different between lens materials (p < 0.001). The central epithelium thinned by 10.0 +/- 4.5% in the MenZ eye and by 10.2 +/- 8.5% in the EqII eye, with the mid-peripheral epithelium thickening by 13.4 +/- 7.9% in the MenZ eye and 18.3 +/- 9.8% in the EqII eye (all changes different from baseline p < 0.001). These epithelial values were not statistically different between materials (p > 0.05). Stromal swelling values on lens removal were 5.7 +/- 2.2% centrally and 5.5 +/- 3.0% mid-peripherally (MenZ) and 7.7 +/- 3.1% centrally and 6.6 +/- 2.9% mid-peripherally (EqII) (all p < 0.001 from baseline). Central stromal swelling was different between eyes at lens removal (p < 0.001). Stromal thickness in both eyes returned to baseline values within 3 h. CONCLUSION The higher-Dk/t MenZ material caused significantly less overnight corneal and stromal swelling than the Eqll material, which reinforces the need to prescribe lenses with high Dk/t for overnight wear. Neither central epithelial thinning nor paracentral thickening are significantly affected by Dk/t.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corneal thickness changes in hyperopic orthokeratology measured by optical pachometry.

PURPOSE To investigate the time course of corneal thickness changes in overnight hyperopic orthokeratology (OK) lens wear for a 4-day lens-wearing period. METHODS Fourteen subjects (age range, 20-37 years) were fitted with hyperopic OK lenses in one eye only. The fellow eye acted as a non-lens wearing control. Lenses were worn overnight only for 4 nights, and changes from baseline in subjecti...

متن کامل

Postoperative Changes in Corneal Epithelial and Stromal Thickness Profiles After Photorefractive Keratectomy in Treatment of Myopia.

PURPOSE To study the corneal epithelial and stromal thickness profile changes after photorefractive keratectomy (PRK) for myopia. METHODS Retrospective analysis of the postoperative corneal epithelial and stromal thickness profile changes in 46 left eyes of 46 patients treated with PRK for myopia. Corneal and epithelial thickness maps within the central 6 mm were obtained by anterior segment ...

متن کامل

همبستگی آستیگماتیسم رفرکتیو، قرنیه‌ای و لنتیکولار در افراد داوطلب جراحی رفرکتیو

Background and purpose: Astigmatism is a common optical dysfunction, effective on various visual outcomes and one of the important criteria of refractive surgery. The aim of present study was to evaluate the correlation between refractive, corneal and residual astigmatism in refractive surgery candidates. Materials and methods: In this cross-sectional descriptive, analytical study, 200 patient...

متن کامل

Epithelial and stromal changes induced by intacs examined by three-dimensional very high-frequency digital ultrasound.

PURPOSE To examine epithelial and stromal layers by three-dimensional very high-frequency (VHF) digital ultrasound scanning before and after implantation of Intacs (intracorneal ring segments [ICRS]). METHODS Three-dimensional scanning was performed in five eyes before and 3 months after Intacs insertion. Digital signal processing techniques provided high-resolution B-scan imaging and I-scan ...

متن کامل

بررسی تغییرات توپوگرافیک قرنیه بعد از اعمال جراحی اسکرال با کلینگ و ویترکتومی

To investigale the topographic changes in the cornea after scleral buckling and vitrectommy. A prospective study was conducted. Thses changes were analyzed based on the type of surgical procedures performed. Design of this study was observational prospective case series. 49 eyes from 48 patients were stratified into four groups based on the type of surgical procedures performed. 10 un...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optometry and vision science : official publication of the American Academy of Optometry

دوره 84 4  شماره 

صفحات  -

تاریخ انتشار 2007