Comparative evaluation of commercial fluorescent treponemal antibody-absorbed test kits.

نویسندگان

  • J L Beebe
  • N J Nouri
چکیده

We describe a comparative evaluation of commercial fluorescent treponemal antibody-absorbed test kits, using 150 selected patient sera. The ability of the test kits to detect reactive sera varied from 82.5 to 95%; that for nonreactive sera varied from 80.9 to 96.4%. Reproducibility of reactive and nonreactive results, measured by between-assay and within-assay studies, averaged 42%. The results showed substantial variation in performance characteristics among the kits, with important clinical implications for the diagnosis of syphilis. We recommend the development of an immunological standard for use in the manufacture of fluorescent treponemal antibody-absorbed test kits, with the goal of obtaining uniform performance characteristics among commercial test kits.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

False-positive reactions in the rapid plasma reagin-card, fluorescent treponemal antibody-absorbed, and hemagglutination treponemal syphilis serology tests.

Sera from 628 nonsyphilitic individuals were tested with the Rapid Plasma Reagin-Card, Fluorescent Treponemal Antibody-Absorbed, and Hemagglutination Treponemal Test for Syphilis tests to ascertain the comparative specificity of these tests. Many sera were also tested with the quantitative Venereal Disease Research Laboratory test. Sera included in the study were from both normal individuals an...

متن کامل

Further evaluation of an automated fluorescent treponemal antibody test for syphilis.

Improvements in the equipment for the automated fluorescent treponemal antibody (AFTA) test for syphilis prompted this comparative study of the AFTA and its manual counterpart, the fluorescent treponemal antibody-absorption (FTA-ABS) test. The AFTA equipment operated satisfactorily, required only minimal monitoring, and afforded a three-to fourfold increase over the number of sera that could be...

متن کامل

Immunochemical parameters of some commercial conjugates for the fluorescent treponemal antibody-absorption test.

Fluorescein-labeled anti-human globulins were examined to determine the need for standardization of conjugates used in the fluorescent treponemal antibody-absorption (FTA-ABS) test. Twenty-one of 33 conjugates submitted by commercial manufacturers to the Reagents Control Activity, Venereal Disease Research Laboratory, for evaluation in the FTA-ABS test were available for study. Conjugates, afte...

متن کامل

Percoll-purified Treponema pallidum, an improved fluorescent treponemal antibody-absorbed antigen.

Percoll-purified Treponema pallidum was evaluated as a fluorescent treponemal antibody-absorbed antigen. Borderline and false-positive reactions were essentially eliminated, resulting in sensitivity and specificity of 100 and 95.5%, respectively. The lack of background debris improved the ease and speed of reading the test.

متن کامل

Automated fluorescent treponemal antibody test: instrument and evaluation.

Two evaluations of the automated fluorescent treponemal antibody (AFTA) test for the serodiagnosis of syphilis are described. The results of AFTA and manually performed fluorescent treponemal antibody-absorption (FTA-ABS) tests were compared on serum samples from clinically defined donor groups, and the reproducibility of each procedure was studied. Significant improvement of AFTA test results ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 19 6  شماره 

صفحات  -

تاریخ انتشار 1984