In vivo and ex vivo measurement of polyethylene wear in total hip arthroplasty

نویسندگان

  • Dov Goldvasser
  • Viktor J Hansen
  • Marilyn E Noz
  • Gerald Q Maguire
  • Michael P Zeleznik
  • Henrik Olivecrona
  • Charles R Bragdon
  • Lars Weidenhielm
  • Henrik Malchau
چکیده

BACKGROUND Determination of the amount of wear in a polyethylene liner following total hip arthroplasty (THA) is important for both the clinical care of individual patients and the development of new types of liners. PATIENTS AND METHODS We measured in vivo wear of the polyethylene liner using computed tomography (CT) (obtained in the course of regular clinical care) and compared it to coordinate-measuring machine (CMM) readings. Also, changes in liner thickness of the same retrieved polyethylene liner were measured using a micrometer, and were compared to CT and CMM measurements. The distance between the centers of the acetabular cup and femoral head component was measured in 3D CT, using a semi-automatic analysis method. CMM readings were performed on each acetabular liner and data were analyzed using 3D computer-aided design software. Micrometer readings compared the thickest and thinnest regions of the liner. We analyzed 10 THA CTs and retrievals that met minimal requirements for CT slice thickness and explanted cup condition. RESULTS - For the 10 cups, the mean difference between the CT readings and the CMM readings was -0.09 (-0.38 to 0.20) mm. This difference was not statistically significant (p = 0.6). Between CT and micrometer, the mean difference was 0.11 (-0.33 to 0.55) mm. This difference was not statistically significant (p = 0.6). INTERPRETATION - Our results show that CT imaging is ready to be used as a tool in clinical wear measurement of polyethylene liners used in THA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In Vivo Wear Particles of Annealed Highly Cross-Linked Polyethylene in Total Hip Arthropalsty

INTRODUCTION: Polyethylene wear particles induce cytokine release by macrophage, which leads to osteolysis and aseptic loosening in total joint arthroplasties. Generation of polyethylene wear particles is one of the most important factors that affecting mid-term and long-term results of total hip arthroplasty (THA). Therefore, to reduce wear generation and to achieve better long-term results of...

متن کامل

In Vivo Wear Particles of Remelted Highly Cross-Linked Polyethylene in Total Hip Arthropalsty

INTRODUCTION: Polyethylene wear particles induce cytokine release by macrophage, which leads to osteolysis and aseptic loosening in total joint arthroplasties. Generation of polyethylene wear particles is one of the most important factors that affecting mid-term and long-term results of total hip arthroplasty (THA). Therefore, to reduce wear generation and to achieve better long-term results of...

متن کامل

In vivo wear particles of remelted highly crosslinked polyethylene after total hip arthroplasty: report of four cases.

This is the first report of in vivo wear particles from four total hip arthroplasties using remelted highly crosslinked polyethylene. The number of particles was (1.51 ± 0.45) × 10(7) g(-1) (mean ± standard error); particle size (equivalent circle diameter), 0.72 ± 0.15 µm; and roundness, 1.45 ± 0.05. Remelted highly crosslinked polyethylene generates fewer, rounder, equivalently sized particle...

متن کامل

Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty

The long-term durability of polyethylene lining total hip arthroplasty (THA) mainly depends on periprosthetic osteolysis due to wear particles, especially in young active patients. In hip simulator study, reports revealed significant wear reduction of the alumina ceramic-on-polyethylene articulation of THA compared with metal-on-polyethylene bearing surfaces. However, medium to long-term clinic...

متن کامل

Wear of retrieved UHMWPE hip liners.

After the gamma-irradiation sterilization, the most widely used orthopaedic grade polymer bearing liner material for the total joint replacement, ultra-high molecular weight polyethylene (UHMWPE), degrades through the progressive in vivo oxidation. The oxidative degradation makes UHMWPE brittle and leads to reduction of its mechanical properties. In this study, the effect of the in vivo post-ir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 85  شماره 

صفحات  -

تاریخ انتشار 2014