Ion effects in measurement of ionized calcium with a calcium-selective electrode.
نویسندگان
چکیده
We examined the performance characteristics of an improved electrode for measurement of ionized calcium (Orion Research, Inc.) with respect to interferences by Na+, K+, Li+, Mg2+, and H+, as well as the effect of changes in ionic strength and osmolality. At physiologically observed concentrations, all ions except Na+ insignificantly affected ionized-calcium measurements. The decrease in ionized Ca2+ with increased Na+ concentration is caused by the increase in ionic strength and the associated decrease in Ca2+ activity. Sodium had no significant direct effect in concentrations below 250 mmol/L. A previously published (Clin. Chem. 23: 690, 1977) equation for the Na+ correction is invalid for this improved electrode. Changes in osmotic pressure negligibly affect electrode response. Significant changes in ionic strength, as would be observed in severe hypo- and hypernatremic sera, increase or decrease, respectively, values for ionized calcium by changing Ca2+ activity. With aqueous Ca2+ solutions, changes of less than or equal to 3% were observed for Na+ concentrations that deviate from 140 mmol/L by not more than 20 mmol/L. Because the calcium ion activity is considered to be the physiologically important variable, we suggest that no correlation be made for ionic strength effects.
منابع مشابه
Activity and interference effects in measurement of ionized calcium with ion-selective electrodes.
We assessed the magnitude of the errors in ionized-calcium measurements resulting from changes in electrolyte composition for three different ion-selective electrodes: the Orion Model 93-20, the Radiometer F2112, and the Simon neutral carrier membrane electrode. We attempted to distinguish between errors arising from changes in calcium ion activity and those due to interferences in the electrod...
متن کاملA Calculation Model for Serum Ionized Calcium Based on an Equilibrium Equation for Complexation
Measurement of ionized calcium is more important than measurement of total calcium in serum samples. In the present study, equations were derived from complexation and acid dissociation equilibrium equations, and were used to determine the concentration of ionized calcium from the observed serum concentrations of total calcium, albumin, total protein, and inorganic phosphate. The ionized calciu...
متن کاملIonized calcium: its significance and clinical usefulness.
Maintenance of normal blood levels of ionized calcium (Ca2+) plays an important role in the management of the critically ill patient. Therefore, Ca2+ should be collected properly and measured reliably. The sound analytical performance of today's Ca2+ analyzers using ion-selective electrode technology have made measurements accurate and precise. The introduction of this technology allows rapid a...
متن کاملA readily available source of serum for use as a precision quality-control material for ionized calcium measurement by ion-selective electrodes
A readily available source of serum ft r use as a precision quality-control material for ionized calcium measurement by ion-selective electrodes A simple method for preparing human serum for use as a precision quality-control for ionized calcium using an ion-selective electrode has been described earlier [1-1. Human citrate dextrose plasma is readily available from outdated whole blood from blo...
متن کاملDetermination of serum ionic calcium with an ion-selective electrode: evaluation of methodology and normal values.
Ionized calcium in serum has been determined potentiometrically by using a calcium ion-selective electrode in a flow.through configuration. For 397 normal human adults the mean value for serum ionic calcium was 1.22 ± 0.09(2 SD) mmol/Iiter. Factors affecting the measurement-such as the pro. cedure for sample collection, sample storage, the preparation of standard solutions, the type of resin em...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 26 5 شماره
صفحات -
تاریخ انتشار 1980