Close genetic relationship between Legionella pneumophila serogroup 1 isolates from sputum specimens and puddles on roads, as determined by sequence-based typing.

نویسندگان

  • Jun-ichi Kanatani
  • Junko Isobe
  • Keiko Kimata
  • Tomoko Shima
  • Miwako Shimizu
  • Fumiaki Kura
  • Tetsutaro Sata
  • Masanori Watahiki
چکیده

We investigated the prevalence of Legionella species isolated from puddles on asphalt roads. In addition, we carried out sequence-based typing (SBT) analysis on the genetic relationship between L. pneumophila serogroup 1 (SG 1) isolates from puddles and from stock strains previously obtained from sputum specimens and public baths. Sixty-nine water samples were collected from puddles on roads at 6 fixed locations. Legionella species were detected in 33 samples (47.8%) regardless of season. Among the 325 isolates from puddles, strains of L. pneumophila SG 1, a major causative agent of Legionnaires' disease, were the most frequently isolated (n = 62, 19.1%). Sixty-two isolates of L. pneumophila SG 1 from puddles were classified into 36 sequence types (STs) by SBT. ST120 and ST48 were identified as major STs. Environmental ST120 strains from puddles were found for the first time in this study. Among the 14 STs of the clinical isolates (n = 19), 4 STs (n = 6, 31.6%), including ST120, were also detected in isolates from puddles on roads, and the sources of infection in these cases remained unclear. The lag-1 gene, a tentative marker for clinical isolates, was prevalent in puddle isolates (61.3%). Our findings suggest that puddles on asphalt roads serve as potential reservoirs for L. pneumophila in the environment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sequence-based typing of Legionella pneumophila serogroup 1 clinical isolates from Belgium between 2000 and 2010.

Sequence-based typing (SBT) is a discriminatory method widely used to genotype Legionella pneumophila strains. A total of 86 clinical L. pneumophila serogroup 1 (sg1) isolates, collected between January 2000 and December 2010 in the two Belgian National Reference Centres for Legionella pneumophila, were genotyped using the internationally standardised SBT protocol of the European Working Group ...

متن کامل

Distribution of sequence-based types of legionella pneumophila serogroup 1 strains isolated from cooling towers, hot springs, and potable water systems in China.

Legionella pneumophila serogroup 1 causes Legionnaires' disease. Water systems contaminated with Legionella are the implicated sources of Legionnaires' disease. This study analyzed L. pneumophila serogroup 1 strains in China using sequence-based typing. Strains were isolated from cooling towers (n = 96), hot springs (n = 42), and potable water systems (n = 26). Isolates from cooling towers, hot...

متن کامل

Antigenic and genetic variation in Legionella pneumophila serogroup 6.

Legionella pneumophila subsp. pneumophila serogroup 6 is second in importance only to L. pneumophila serogroup 1 as a cause of legionellosis. Monoclonal antibody (MAb) reactivity and multilocus enzyme electrophoretic analyses were used to subtype serogroup 6 isolates as a potential aid for epidemiologic and virulence studies. Forty-eight serogroup 6 isolates submitted to the Centers for Disease...

متن کامل

Genomic Characterization of a Large Outbreak of Legionella pneumophila Serogroup 1 Strains in Quebec City, 2012

During the summer of 2012, a major Legionella pneumophila serogroup 1 outbreak occurred in Quebec City, Canada, which caused 182 declared cases of Legionnaire's disease and included 13 fatalities. Legionella pneumophila serogroup 1 isolates from 23 patients as well as from 32 cooling towers located in the vicinity of the outbreak were recovered for analysis. In addition, 6 isolates from the 199...

متن کامل

Legionella pneumonia due to exposure to 24-hour bath water contaminated by Legionella pneumophila serogroup-5.

A 79-year-old man was admitted to hospital from his nursing home for treatment of pneumonia, but died 7 days after admission. Legionella pneumonia was diagnosed after isolation of Legionella pneumophila serogroup-5 from sputum culture. The environment of the nursing home was investigated; only water specimens from the 24-hour bath were positive by culture for Legionella pneumophila serogroup-5....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 79 13  شماره 

صفحات  -

تاریخ انتشار 2013