Intra-frame Motion Compensation in Multi-frame Brain PET Imaging
نویسندگان
چکیده
PurposeInter-frame and intra-frame motion can adversely impact the performance of dynamic brain PET imaging. Only correcting the former can still result in degraded qualitative and quantitative performance. Meanwhile, patient motion introduces mismatches between transmission and emission data which may lead to incorrect attenuation and scatter compensation in the reconstruction process. As a result, the reconstructed dynamic images may carry erroneous estimates of radioactivity distribution. We seek a solution to this problem. MethodsWe investigated the use of iterative deconvolution coupled with a proposed use of time-weighted averaging of motion-transformed transmission images to correct the transmission-emission mismatch artifacts in dynamic brain PET images. We performed simulations using real-patient motion profile acquired by the infrared Polaris Vicra motion tracking device which estimates 3-D motion transformations during PET acquisition. This was followed by frame-based motion correction employing three different transmission-emission alignment strategies: transmission image transformed by (1) mean motion transformation, (2) median motion transformation, and (3) the proposed time-weighted average of motion-transformed transmission images. ResultsThe results demonstrate that the proposed approach of using time-weighted averaging of motion transformed transmission images outperforms conventional methods by substantially reducing the transmission-emission mismatch artifacts in the reconstructed images. Coupled with an alignment of the reconstructed frames for inter-frame motion correction and a subsequent iterative deconvolution approach for intra-frame motion correction, the resulting motion compensated images showed superior quality, considerable reduction in error norm and enhanced noise-bias performance compared to conventional methods of transmission-emission mismatch compensation. The performance was consistent across different levels of intra-frame motion, and the algorithm was amenable to different framing schemes. ConclusionIn frame-based motion correction of dynamic PET images, it is feasible to achieve intra-frame motion compensation using time-weighted averaging of motion transformed transmission images coupled with a post-reconstruction iterative deconvolution procedure to compensate for intra-frame motion. * Corresponding Author: Hassan Mohy-ud-Din, PhD Department of Diagnostic Radioloy, Yale School of Medicine, Yale University Tel: (+1) 443-301-7004, E-mail:[email protected] P
منابع مشابه
Compensation of Intra-Frame Head Motion in PET Data with Motion Corrected Independent Component Analysis (MCICA)
Independent Component Analysis (ICA) has proved a powerful exploratory analysis method for fMRI. In the ICA model, the fMRI data at a given time point are modeled as the linear superposition of spatially independent (and spatially stationary) component maps. The ICA model has been recently applied to positron emission tomography (PET) data with some success (Human Brain Mapping 18:284-295(2003)...
متن کاملQuantitative PET image reconstruction employing nested expectation-maximization deconvolution for motion compensation
Bulk body motion may randomly occur during PET acquisitions introducing blurring, attenuation-emission mismatches and, in dynamic PET, discontinuities in the measured time activity curves between consecutive frames. Meanwhile, dynamic PET scans are longer, thus increasing the probability of bulk motion. In this study, we propose a streamlined 3D PET motion-compensated image reconstruction (3D-M...
متن کاملImpact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer
AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...
متن کاملPartition coding using multi-grid chain code and motion compensation
In this paper, a lossy partition coding technique is presented which leads to decoded partitions with unnoticeable losses. It uses an hexagonal grid for contour representation and it is based on the concept of Multi-Grid Chain Code. This coding technique can be used in intra-frame mode or, in combination with partition prediction techniques, in inter-frame mode. In intra-frame mode, it leads to...
متن کاملAdvanced Motion Correction Methods in PET
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...