Predicting right ventricular failure in the modern, continuous flow left ventricular assist device era.

نویسندگان

  • Pavan Atluri
  • Andrew B Goldstone
  • Alex S Fairman
  • John W MacArthur
  • Yasuhiro Shudo
  • Jeffrey E Cohen
  • Alexandra L Acker
  • William Hiesinger
  • Jessica L Howard
  • Michael A Acker
  • Y Joseph Woo
چکیده

BACKGROUND In the era of destination continuous flow left ventricular assist devices (LVAD), the decision of whether a patient will tolerate isolated LVAD support or will need biventricular support (BIVAD) can be challenging. Incorrect decision making with delayed right ventricular (RV) assist device implantation results in increased morbidity and mortality. Continuous flow LVADs have been shown to decrease pulmonary hypertension and improve RV function. We undertook this study to determine predictors in the continuous flow LVAD era that identify patients who are candidates for isolated LVAD therapy as opposed to biventricular support. METHODS We reviewed demographic, hemodynamic, laboratory, and echocardiographic variables for 218 patients who underwent VAD implant from 2003 through 2011 (LVAD=167, BIVAD=51), during the era of continuous flow LVADs. RESULTS Fifty preoperative risk factors were compared between patients who were successfully managed with an LVAD and those who required a BIVAD. Seventeen variables demonstrated statistical significance by univariate analysis. Multivariable logistic regression analysis identified central venous pressure>15 mmHg (OR 2.0, "C"), severe RV dysfunction (OR 3.7, "R"), preoperative intubation (OR 4.3, "I"), severe tricuspid regurgitation (OR 4.1, "T"), heart rate>100 (OR 2.0, Tachycardia-"T")-CRITT as the major criteria predictive of the need for biventricular support. Utilizing these data, a highly sensitive and easy to use risk score for determining RV failure was generated that outperformed other established risk stratification tools. CONCLUSIONS We present a preoperative risk calculator to determine suitability of a patient for isolated LVAD support in the current continuous flow ventricular assist device era.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes.

OBJECTIVE The aim of this study was to evaluate the incidence, risk factors, and effect on outcomes of right ventricular failure in a large population of patients implanted with continuous-flow left ventricular assist devices. METHODS Patients (n = 484) enrolled in the HeartMate II left ventricular assist device (Thoratec, Pleasanton, Calif) bridge-to-transplantation clinical trial were exami...

متن کامل

Beneficial aspects of real time flow measurements for the management of acute right ventricular heart failure following continuous flow ventricular assist device implantation

BACKGROUND Optimal management of acute right heart failure following the implantation of a left ventricular assist device requires a reliable estimation of left ventricular preload and contractility. This is possible by real-time pump blood flow measurements. CLINICAL CASE We performed implantation of a continuous flow left ventricular assist device in a 66 years old female patient with an en...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Annals of thoracic surgery

دوره 96 3  شماره 

صفحات  -