Modulation of neonatal growth plate development by ex vivo intermittent mechanical stress.

نویسندگان

  • Hasan Othman
  • Eugene J Thonar
  • Jeremy J Mao
چکیده

Although growth plate response to mechanical stress has been increasingly studied, our understanding of mechanical modulation of neonatal growth plate is incomplete, especially concerning biochemical changes. This study was designed to explore the cellular and biochemical responses of the cranial base growth plate (CBGP) explant upon cyclic loading. The growth plate with subchondral bone was aseptically isolated from each of 24 neonatal rabbits and fixated in an organ culture system. Cyclic loading was applied to growth plate explants at 200 mN and 1 Hz for 60 min (N=12), whereas control explants were immersed in organ culture for 60 min without mechanical loading (N=12). Computerized image analysis revealed that cyclic loading induced significantly more proliferating chondrocytes than unloaded controls (p<0.001), as well as significantly higher growth plate height at 856+/-30 microm than the unloaded controls at 830+/-36 microm (p<0.05). Immunoblotting with monoclonal antibodies (mAb) disclosed that the average mAb binding area for chondroitin sulfate was significantly higher in the loaded specimens than the unloaded controls at (p<0.001). The average mAb binding area for keratan sulfate was also significantly higher in the loaded specimens than the unloaded controls (p<0.01). Biochemical analysis showed that the average total hyaluronan content of loaded specimens at 0.25+/-0.06 microg/microg DNA was significantly higher than the unloaded controls at 0.09+/-0.05 microg/microg DNA (p<0.01). Taken together, these data suggest that brief doses of cyclic, intermittent forces activate cellular and molecular responses in the CBGP ex vivo. Whether hyaluronan-mediated pathway is involved in the biological responses of growth plate to mechanical loading warrants additional investigations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changes in growth plate extracellular matrix composition and biomechanics following in vitro static versus dynamic mechanical modulation

The objective of this study was to investigate the effects of mechanical modulation parameters on structural proteins biocomposition and mechanical properties of the growth plate. Establishing these parameters is a crucial step in the development of fusionless treatment of scoliosis. In this study, ulna explants from 4-weeks-old (pubertal) swines were used. The biocomposition was characterized ...

متن کامل

Intermittent Compressive Stress Enhanced Insulin-Like Growth Factor-1 Expression in Human Periodontal Ligament Cells

Mechanical force was shown to promote IGF-1 expression in periodontal ligament both in vitro and in vivo. Though the mechanism of this effect has not yet been proved, here we investigated the molecular mechanism of intermittent mechanical stress on IGF-1 expression. In addition, the role of hypoxia on the intermittent compressive stress on IGF-1 expression was also examined. In this study, huma...

متن کامل

Chondrocyte-specific modulation of Cyp27b1 expression supports a role for local synthesis of 1,25-dihydroxyvitamin D3 in growth plate development.

The Cyp27b1 enzyme (25-hydroxyvitamin D-1alpha-hydroxylase) that converts 25-hydroxyvitamin D into the active metabolite, 1,25-dihydroxyvitamin D(3) [1,25(OH)(2)D(3)], is expressed in kidney but also in other cell types such as chondrocytes. This suggests that local production of 1,25(OH)(2)D(3) could play an important role in the differentiation of these cells. To test this hypothesis, we engi...

متن کامل

Neonatal exendin-4 treatment reduces oxidative stress and prevents hepatic insulin resistance in intrauterine growth-retarded rats.

Intrauterine growth retardation (IUGR) has been linked to the development of type 2 diabetes in adulthood. We have developed an IUGR model in the rat whereby the animals develop diabetes later in life. Previous studies demonstrate that administration of the long-acting glucagon-like-peptide-1 agonist, exendin-4, during the neonatal period prevents the development of diabetes in IUGR rats. IUGR ...

متن کامل

Comparison of Continuous and Intermittent Feeding Methods in Low Birth Weight Infants

Objective About 1 % of infants are of very low birth weight. However, they comprise about 50% of infant mortality. We compare the effects of continuous versus intermittent feeding on physical growth, gastrointestinal tolerance and macronutrient retention in low birth weight infants (Methods A prospective randomized trial clinical trial was performed from 2004-2005. Very low birth weight neonate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 40 12  شماره 

صفحات  -

تاریخ انتشار 2007