Euglobulin lysis times: an update.
نویسندگان
چکیده
UNLABELLED There are several clot lysis tests available to assess the presence of increased fibrinolysis in a clinical situation. These include whole blood, plasma, and "eugloblin" lysis tests. The euglobulin lysis test (ELT) is actually a modified plasma clot lysis time, which detects increased plasminogen activation and subsequent fibrinolysis. It does not detect the activity of antiplasmins. The purpose of this study was to determine ELT for a group of 25 ambulatory normals. There were 10 males and 15 females, ranging in age from 25 to 56 years. Citrate anticoagulated samples were obtained immediately after application of a tourniquet and 10 minutes after application of a sphygmomanometer inflated to midway between systolic and diastolic pressure. The citrated plasma was precipitated with cold acetic acid. The precipitate contained fibrinogen, plasminogen, and plasminogen activators, with fibrinolytic inhibitors theoretically removed. The precipitate was redissolved and the euglobulin solution was clotted with thrombin. The clotted sample was then incubated at 37 degrees C and was observed at 10 minute intervals for clot lysis. RESULTS The reference range of onset of fibrinolysis was from 1.25 to 12 hours, with a mean of 3.78 hours +/- 2.45 hours (1 S.D.). Venostasis (use of the sphygmomanometer) resulted in an ELT that was shorter than the non-venostasis specimens in 11 of 25 specimens. This is thought to be secondary to in vivo activation of plasminogen. CONCLUSION The average euglobulin lysis time in 25 ambulatory normals is approximately 3.5 hours. The ELTs vary over a broad range (1.25 to 12.0 hours) in normal ambulatory volunteers.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
The euglobulin lysis time test: an ineffectual monitor of the therapeutic inhibition of fibrinolysis.
In two clinical situations associated with hyperfibrinolysis the administration of antifibrinolytic drugs resulted in clinical haemostasis. The dilute clot lysis time and fibrin plate activity test but not the euglobulin lysis time reflected this control of excessive fibrinolysis by the antifibrinolytic drugs. The inhibition by epsilon-amino-caproic acid (EACA) of hyperfibrinolysis induced in v...
متن کاملAutomatic determination of euglobulin lysis time.
Despite the criticisms of substrate variability, the euglobulin lysis time remains a most useful assay of plasma plasminogen activator. It is simple to execute and correlates well with the radioactive clot assay (Sawyer, Fletcher, Alkjaersig, and Sherry, 1960), dilute blood clot lysis time (Fearnley, Balmforth, and Feamley, 1957), and fibrin plate method (Kekwick and Mackay, 1954). It continues...
متن کاملA new device for measurement of fibrin clot lysis: application to the Euglobulin Clot Lysis Time
BACKGROUND Determination of clot lysis times on whole blood, diluted whole blood, plasma or plasma fraction has been used for many years to assess the overall activity of the fibrinolytic system. We designed a completely computerised semi-automatic 8-channel device for measurement and determination of fibrin clot lysis. The lysis time is evaluated by a mathematical analysis of the lysis curve a...
متن کاملSerum fibrin degradation products throughout normal pregnancy.
Fibrin/fibrinogen degradation products in the serum of 169 healthy pregnant and 43 healthy non-pregnant subjects of a similar age group showed a significant increase throughout pregnancy, the highest levels being obtained in the third trimester. There was no correlation with plasma fibrinogen levels or euglobulin lysis times. Though these changes may be due to other alterations in pregnancy not...
متن کاملMethodological study and a recommended technique for determining the euglobulin lysis time.
The euglobulin lysis time, which is widely used to measure blood fibrinolytic activity, is shown to be sensitive to the temperature and pH at which the euglobulin fraction of plasma is prepared and also to the type of anticoagulant employed and buffer in which it is suspended. A standardized method for performing the test, which controls these variables and has been found to yield reproducible ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of clinical and laboratory science
دوره 23 5 شماره
صفحات -
تاریخ انتشار 1993