Is optical imaging spectroscopy a viable measurement technique for the investigation of the negative BOLD phenomenon? A concurrent optical imaging spectroscopy and fMRI study at high field (7 T)
نویسندگان
چکیده
Traditionally functional magnetic resonance imaging (fMRI) has been used to map activity in the human brain by measuring increases in the Blood Oxygenation Level Dependent (BOLD) signal. Often accompanying positive BOLD fMRI signal changes are sustained negative signal changes. Previous studies investigating the neurovascular coupling mechanisms of the negative BOLD phenomenon have used concurrent 2D-optical imaging spectroscopy (2D-OIS) and electrophysiology (Boorman et al., 2010). These experiments suggested that the negative BOLD signal in response to whisker stimulation was a result of an increase in deoxy-haemoglobin and reduced multi-unit activity in the deep cortical layers. However, Boorman et al. (2010) did not measure the BOLD and haemodynamic response concurrently and so could not quantitatively compare either the spatial maps or the 2D-OIS and fMRI time series directly. Furthermore their study utilised a homogeneous tissue model in which is predominantly sensitive to haemodynamic changes in more superficial layers. Here we test whether the 2D-OIS technique is appropriate for studies of negative BOLD. We used concurrent fMRI with 2D-OIS techniques for the investigation of the haemodynamics underlying the negative BOLD at 7 Tesla. We investigated whether optical methods could be used to accurately map and measure the negative BOLD phenomenon by using 2D-OIS haemodynamic data to derive predictions from a biophysical model of BOLD signal changes. We showed that despite the deep cortical origin of the negative BOLD response, if an appropriate heterogeneous tissue model is used in the spectroscopic analysis then 2D-OIS can be used to investigate the negative BOLD phenomenon.
منابع مشابه
Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI
Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...
متن کاملNonlinear Optical Properties of Rigid Polyurethane Foam/SiO2 Nanocomposite
Polyurethane closed cell (PUCC)/SiO2 nanocomposites have been prepared by using in situ polymerization approach. The third-order optical nonlinearities of PUCC/SiO2 nanocomposites, dissolved in DMF are characterized by Z-scan technique at the measurement wavelength of 532 nm. The nonlinear refractive (NLR) indices and nonlinear absorption (NLA) coefficients of samples were calculated from close...
متن کاملRefinement of optical imaging spectroscopy algorithms using concurrent BOLD and CBV fMRI
We describe the use of the three dimensional characteristics of the functional magnetic resonance imaging (fMRI) blood oxygenation level dependent (BOLD) and cerebral blood volume (CBV) MRI signal changes to refine a two dimensional optical imaging spectroscopy (OIS) algorithm. The cortical depth profiles of the BOLD and CBV changes following neural activation were used to parameterise a 5-laye...
متن کاملNonlinear Optical Investigation of Biochemical Analytes in Blood Serum via Z-Scan Technique
Background and Aims: Biomolecules' optical and nonlinear optical properties are widely used for different medical diagnoses and applications in biophotonic devices. These properties are essential in studying biological processes in living tissues. Aside from biomolecules' linear optical characteristics, their nonlinear optical characteristics have lately been considered. Materials and Methods:...
متن کاملInvestigation in to Properties of Polyurethane Closed Cell by High Loading of SiO2 Nanoparticles
In this research the composition of polyurethane closed cell (PUCC) with two different concentrations of SiO2 nanoparticles (1.0 and 2.0 wt%) have been prepared. Optical microscopy and SEM imaging, watering uptake, FTIR and Raman spectroscopy of the synthesized samples were carried out. The optical microscopy imaging of samples showed differences in the appearance of matrix produ...
متن کامل