Using CBCT for pretreatment range check in proton therapy: a phantom study for prostate treatment by anterior–posterior beam

نویسندگان

  • El Hassane Bentefour
  • Stefan Both
  • Shikui Tang
  • Hsiao‐Ming Lu
چکیده

This study explores the potential of cone-beam computed tomography (CBCT) for monitoring relative beam range variations due to daily changes in patient anatomy for prostate treatment by anterior proton beams. CBCT was used to image an anthropomorphic pelvic phantom, in eight sessions on eight different days. In each session, the phantom was scanned twice, first at a standard position as determined by the room lasers, and then after it was shifted by 10 mm translation randomly along one of the X, Y, or Z directions. The filling of the phantom bladder with water was not refreshed from day to day, inducing gradual change of the water-equivalent path length (WEPL) across the bladder. MIMvista (MIM) software was used to perform image registration and re-alignment of all the scans with the scan from the first session. The XiO treatment planning system was used to perform data analysis. It was found that, although the Hounsfield unit numbers in CBCT have substantially larger fluctuations than those in diagnostic CT, CBCT datasets taken for daily patient positioning could potentially be used to monitor changes in patient anatomy. The reproducibility of the WEPL, computed using CBCT along anterior-posterior (AP) paths across and around the phantom prostate, over a volume of 360 cc, is sufficient for detecting daily WEPL variations that are equal to or larger than 3 mm. This result also applies to CBCT scans of the phantom after it is randomly shifted from the treatment position by 10 mm. limiting the interest to WEPL variation over a specific path within the same CBCT slice, one can detect WEPL variation smaller than 1 mm. That is the case when using CBCT for tracking daily change of the WEPL across the phantom bladder that was induced by spontaneous change in the bladder filling due to evaporation. In summary, the phantom study suggests that CBCT can be used for monitoring day to day WEPL variations in a patient. The method can detect WEPL variation equal to or greater than 3 mm. The study calls for further investigation using the CBCT data from real patients. If confirmed with real patients' data, CBCT could become, in addition to patient setup, a standard tool for proton therapy pretreatment beam range check.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography

Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomograph...

متن کامل

Monte Carlo calculations of dose distribution for the treatment of gastric cancer with proton therapy

Proton therapy is a common form of external radiation therapy based on the manipulation of Bragg peak of this beam, it can treat the tumor by delivering high levels of doses to it, while protecting surrounding healthy tissues against radiation. In this work, the dose distribution of proton and secondary particles such as neutrons, photons, electrons and positrons in gastric cancer proton therap...

متن کامل

Impact of range straggling and multiple scattering on proton therapy of brain, using a slab head phantom

Background: The advantages of proton beam in radiation therapy- like small lateral scattering as well as absence of exit dose tail in the organs which are after the tumor- make it capable of delivering more treatment doses to the target and much lesser to the critical tissues near it. Materials and Methods: In this study, the Monte Carlo MCNPX code has been used to simulate a slab head phantom ...

متن کامل

Tissue inhomogeneity in proton therapy and investigation of its effects on BRAGG peak by using MCNPX code

Background: Hadron therapy for malignant tumor is becoming increasingly popular. There are many factors which effect on implementation of a proper treatment planning. The purpose of this work is to investigate the inhomogeneity effects as affecting factor on proton range, Full width at half maximum (FWHM) and 20% position of penumbra (P20) by MCNPX code. Materials and Methods: An inhomogeneous ...

متن کامل

A new model for Spread Out Bragg Peak in proton therapy of uveal melanoma

In this research, in order to improve our calculations in treatment planning for proton radiotherapy of ocular melanoma, we improved our human eye phantom planning system in GEANT4 toolkit. Different analytical models have investigated the creating of Spread Out Bragg Peak (SOBP) in the tumor area. Bortfeld’s model is one of the most important analytical methods. Using convolution method, a new...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015