Correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes

نویسندگان

  • Bruno P Figueiredo
  • Sebastião Cronemberger
  • Fabio N Kanadani
چکیده

BACKGROUND The purpose of this study was to investigate the correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes. METHODS Ninety eyes from 90 patients were included. Thirty patients had been recently diagnosed with glaucoma and had no previous history of treatment for ocular hypotension, 30 had elevated intraocular pressure (IOP) without evidence of glaucoma, and 30 had normal IOP (<21 mmHg) with no detectable glaucomatous damage. Goldmann applanation tonometry (GAT), dynamic contour tonometry (DCT), blood pressure measurement, pachymetry, Humphrey visual field, and routine ophthalmic examination was performed in each patient. Ocular perfusion pressure was calculated as the difference between mean arterial pressure and IOP. The ocular pulse amplitude was given by DCT. The Pearson correlation coefficient was used to compare the glaucomatous and ocular hypertensive groups, and comparisons with the normal IOP group were done using the Spearman's rank correlation coefficient. RESULTS Mean IOP by DCT was 22.7 ± 4.3 mmHg in the glaucoma group, 22.3 ± 2.8 mmHg in the ocular hypertension group, and 14.3 ± 1.6 mmHg in the control group. Mean IOP by GAT was 19.0 ± 5.1 mmHg for glaucoma, 22.4 ± 2.1 mmHg for ocular hypertension, and 12.9 ± 2.2 mmHg for controls. Mean ocular pulse amplitude was 3.4 ± 1.2 mmHg in the glaucoma group, 3.5 ± 1.2 mmHg in the ocular hypertension group, and 2.6 ± 0.9 mmHg in the control group. Mean ocular perfusion pressure was 46.3 ± 7.9 mmHg in the glaucoma group, 46.3 ± 7.9 mmHg in the ocular hypertension group, and 50.2 ± 7.0 mmHg in controls. No significant correlation between ocular perfusion pressure and ocular pulse amplitude was found in any of the groups (P = 0.865 and r = -0.032, P = 0.403 and r = -0.156, P = 0.082 and ρ = -0.307 for glaucoma, ocular hypertension, and normal eyes, respectively). CONCLUSION There is no significant correlation between ocular perfusion pressure and ocular pulse amplitude values in glaucoma, ocular hypertension, or normal eyes. IOP values measured by GAT correlate with those measured by DCT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه تاثیر تیمولول و بتاکسولول بر کاهش فشار داخل چشمی و عوارض موضعی و سیستمیک آنها

Background and purpose: This is a study to compare the efficacy and side effects of betaxolol and timolol in lowering the IOP of primary open angle glaucoma or ocular hypertension. Materials and Methods: This Double-blind randomized cross-over clinical trial was conducted on 29 eyes of 20 patients with primary open angle glaucoma or ocular hypertension. Each patient received timolol 0.5% a...

متن کامل

Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.

PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...

متن کامل

Studies of the ocular pulse in primates.

Ocular pulse amplitude (OPA) and intraocular pressure (IOP) were measured in groups of human subjects with primary open-angle glaucoma (POAG), ocular hypertension (OHT), low-tension glaucoma (LTG), retinal degenerations (RD), in OHT volunteers treated with single doses of 2% epinephrine, 4% pilocarpine, 0.5% timolol or 1% p-amino-clonidine, and in normal subjects before and after exercise. Comp...

متن کامل

Factors affecting ocular pulse amplitude in eyes with open angle glaucoma and glaucoma-suspect eyes.

PURPOSE To investigate the associations between ocular pulse amplitude (OPA) as measured by dynamic contour tonometry (DCT) and ocular and systemic factors in patients with open angle glaucoma (OAG) and in glaucoma suspects. METHODS One hundred and seventy-three glaucoma-suspect patients were consecutively enrolled. All subjects underwent intraocular pressure (IOP) measurement by DCT and Gold...

متن کامل

[Ocular pulse amplitude in patients with open-angle glaucoma, normal-tension glaucoma, and ocular hypertensionby dynamic observing tonometry].

PURPOSE The aim of this study was to compare the ocular pulse amplitude (OPA) in patients with different types of glaucoma, and also to evaluate the usefulness of OPA for the elucidation of normal-tension glaucoma (NTG). OPA is thought to reflect choroidal circulation. SUBJECTS Sixty-six patients with normal-tension glaucoma (NTG), 52 patients with primary open angle glaucoma (POAG), 42 with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013