Kinematic “4 Dimensional” CT Imaging in the Assessment of Wrist Biomechanics Before and After Surgical Repair
نویسندگان
چکیده
AIM Describe the use of 320 row detector CT scanner for 4 Dimensional CT acquisition on a specialized platform designed for wrist kinematic evaluation and to demonstrate the utility of 4 Dimensional CT in the assessment of wrist biomechanics before and after surgical repair. MATERIALS AND METHODS Six wrists (1 volunteer and 4 patients) were uniformly imaged with conventional X-rays and 4 Dimensional CT on a 320 row detector CT scanner (Aquilion one, Toshiba, Tokyo, Japan). A dedicated custom designed wrist platform was used for kinematic imaging. Three subjects (3 wrists) had prior fixation of the complex wrist injury. Clinical correlations were obtained. RESULTS All subjects were successfully scanned in various wrist motions. 4 Dimensional CT image quality was adequate and carpal kinematic behavior was easily assessed in various wrist motions both before and after surgical repair. The normal and altered carpal kinematic behaviors correlated well with the clinical findings. In the operated wrists, while X-rays demonstrated slight gapping after scapholunate ligament repair, kinematic imaging demonstrated no abnormal widening on dynamic motion and showed normal dorsally hinged "scissoring" type scapholunate motion with active wrist motion. However, normal mid-carpal initiated wrist motion on flexion/extension was replaced by radiocarpal initiated motion, likely because of midcarpal stiffness/scarring. CONCLUSION 4 Dimensional CT provides adequate and novel assessment of wrist biomechanics both before and after surgical repair.
منابع مشابه
Effect of Fatigue on Knee Kinematics During Countermovement Jumps in Female Students of Physical Education With Valgus Knee Deformity
Objectives: Skeletal-muscular disorders affect the biomechanics of the human body, especially the lower extremity, with a negative effect on the biomechanics of exercise. The main aim of this study was to evaluate the effect of fatigue on the kinematic variables of knee joints during countermovement jumps in female students of physical education with valgus knee deformity. Methods: Fifte...
متن کاملDiagnostic value of CT and MRI of Temporal Bone in Cochlear Implantation Candidates
Background Cochlear implantation is an approved treatment which can be used to treat severe to profound hearing loss. Imaging before cochlear implant surgery is very important in decision making and assessing the temporal bone anatomy for surgery. We aimed to assess the diagnostic value of high resolution CT scan (HRCT), and MRI of temporal bone in candidate pati...
متن کاملInter-observer agreement between 2-dimensional CT versus 3-dimensional I-Space model in the Diagnosis of Occult Scaphoid Fractures
Background: The I-Space is a radiological imaging system in which Computed Tomography (CT)-scans can be evaluated as a three dimensional hologram. The aim of this study is to analyze the value of virtual reality (I-Space) in diagnosing acute occult scaphoid fractures. Methods: A convenient cohort of 24 patients with a CT-scan from prior studies, without a scaphoid fracture on radiograph, ye...
متن کاملSurgical Repair of Giant Type IV Hiatal Hernia
In this case report, we described a 74-year-old female patient with major complaint of respiratory problemsdyspnea after meal. Chest X-ray of the patient revealed a gianttype IV hiatal hernia. Preoperative evaluations of the patient included esophagoscopy, esophageal manometry, barium swallow, and CT-scan. Repair of the hernia was performed using a dual mesh on the diaphragm and partial anteri...
متن کاملKnee Kinematic Improvement After Total Knee Replacement Using a Simplified Quantitative Gait Analysis Method
Objectives: The aim of this study was to extract suitable spatiotemporal and kinematic parameters to determine how Total Knee Replacement (TKR) alters patients’ knee kinematics during gait, using a rapid and simplified quantitative two-dimensional gait analysis procedure. Methods: Two-dimensional kinematic gait pattern of 10 participants were collected before and after the TKR surgery,...
متن کامل